This is the latest recevied telemetry packets stored in our database for station/object N2RWE-13. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vin* | Rx1h* | Dg1h* | Eff1h* | Temp* |
|---|---|---|---|---|---|
| 1786719103 | 13.8 Volt | 120 Pkt | 20 Pkt | 29 Pcnt | 0 C |
| 1786717903 | 13.73 Volt | 160 Pkt | 30 Pkt | 31 Pcnt | 0 C |
| 1786717303 | 12.68 Volt | 160 Pkt | 30 Pkt | 30 Pcnt | 0 C |
| 1786716703 | 13.73 Volt | 170 Pkt | 30 Pkt | 29 Pcnt | 0 C |
| 1786716104 | 12.9 Volt | 170 Pkt | 30 Pkt | 30 Pcnt | 0 C |
| 1786715503 | 13.73 Volt | 160 Pkt | 30 Pkt | 29 Pcnt | 0 C |
| 1786714905 | 13.73 Volt | 140 Pkt | 30 Pkt | 26 Pcnt | 0 C |
| 1786714304 | 13.65 Volt | 140 Pkt | 40 Pkt | 26 Pcnt | 0 C |
| 1786713707 | 13.65 Volt | 150 Pkt | 40 Pkt | 30 Pcnt | 0 C |
| 1786708303 | 13.65 Volt | 110 Pkt | 20 Pkt | 24 Pcnt | 0 C |
| 1786705303 | 13.65 Volt | 120 Pkt | 20 Pkt | 27 Pcnt | 0 C |
| 1786703505 | 13.65 Volt | 130 Pkt | 30 Pkt | 26 Pcnt | 0 C |
| 1786701704 | 13.65 Volt | 170 Pkt | 40 Pkt | 29 Pcnt | 0 C |
| 1786700504 | 13.65 Volt | 230 Pkt | 50 Pkt | 38 Pcnt | 0 C |
| 1786699304 | 13.65 Volt | 230 Pkt | 40 Pkt | 40 Pcnt | 0 C |
| 1786698705 | 13.65 Volt | 240 Pkt | 50 Pkt | 43 Pcnt | 0 C |
| 1786696905 | 13.65 Volt | 250 Pkt | 50 Pkt | 46 Pcnt | 0 C |
| 1786693305 | 13.65 Volt | 230 Pkt | 30 Pkt | 42 Pcnt | 0 C |
| 1786692105 | 13.65 Volt | 230 Pkt | 30 Pkt | 40 Pcnt | 0 C |
| 1786691504 | 13.65 Volt | 230 Pkt | 30 Pkt | 42 Pcnt | 0 C |
| 1786690904 | 13.65 Volt | 220 Pkt | 30 Pkt | 42 Pcnt | 0 C |
| 1786690304 | 13.05 Volt | 210 Pkt | 30 Pkt | 44 Pcnt | 0 C |
| 1786689704 | 13.65 Volt | 200 Pkt | 30 Pkt | 44 Pcnt | 0 C |
| 1786689105 | 13.65 Volt | 190 Pkt | 20 Pkt | 46 Pcnt | 0 C |
| 1786688505 | 13.65 Volt | 160 Pkt | 20 Pkt | 44 Pcnt | 0 C |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Temp: 0, 0.5, -64
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)