This is the latest recevied telemetry packets stored in our database for station/object IR2ZYA. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Rx10m* | Rx1h* | Dg10m* | DgR* | Eff* |
|---|---|---|---|---|---|
| 1836274778 | 40 Pkt | 270 Pkt | 0 Pkt | 1.35 Pcnt | 77 Pcnt |
| 1836274478 | 40 Pkt | 280 Pkt | 0 Pkt | 1.35 Pcnt | 77 Pcnt |
| 1836274328 | 37 Pkt | 270 Pkt | 0 Pkt | 1.34 Pcnt | 77 Pcnt |
| 1836274178 | 38 Pkt | 280 Pkt | 0 Pkt | 1.35 Pcnt | 77 Pcnt |
| 1836273878 | 37 Pkt | 270 Pkt | 0 Pkt | 1.35 Pcnt | 77 Pcnt |
| 1774086510 | 101 Pkt | 520 Pkt | 1 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774086210 | 117 Pkt | 540 Pkt | 1 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774085910 | 85 Pkt | 530 Pkt | 2 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774085610 | 75 Pkt | 530 Pkt | 3 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774085310 | 65 Pkt | 530 Pkt | 3 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774085010 | 70 Pkt | 550 Pkt | 1 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774084710 | 73 Pkt | 540 Pkt | 0 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774084410 | 68 Pkt | 530 Pkt | 0 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774084110 | 83 Pkt | 520 Pkt | 0 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774083810 | 92 Pkt | 510 Pkt | 0 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774083510 | 71 Pkt | 490 Pkt | 0 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774083210 | 95 Pkt | 470 Pkt | 0 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774082910 | 115 Pkt | 470 Pkt | 3 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774082610 | 91 Pkt | 430 Pkt | 4 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774082310 | 90 Pkt | 420 Pkt | 1 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774082010 | 86 Pkt | 410 Pkt | 1 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774081710 | 72 Pkt | 420 Pkt | 1 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774081410 | 53 Pkt | 430 Pkt | 0 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774081110 | 49 Pkt | 460 Pkt | 0 Pkt | 1.38 Pcnt | 74 Pcnt |
| 1774080810 | 50 Pkt | 480 Pkt | 0 Pkt | 1.38 Pcnt | 74 Pcnt |
*Used Equation Coefficients:
Rx10m: 0, 1, 0
Rx1h: 0, 10, 0
Dg10m: 0, 1, 0
DgR: 0, 0.001, 0
Eff: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)