This is the latest recevied telemetry packets stored in our database for station/object SR9NIS. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Rx10min* | Tx10min* | Digi10min* | Vbatt* | Tempre* |
|---|---|---|---|---|---|
| 1790640385 | 7 Pkt | 2 Pkt | 0 Pkt | 13.48 V | 0 DegC |
| 1790639747 | 12 Pkt | 5 Pkt | 0 Pkt | 13.48 V | 0 DegC |
| 1790639118 | 11 Pkt | 2 Pkt | 0 Pkt | 13.5 V | 0 DegC |
| 1790638479 | 17 Pkt | 4 Pkt | 0 Pkt | 13.46 V | 0 DegC |
| 1790637203 | 12 Pkt | 7 Pkt | 0 Pkt | 13.48 V | 0 DegC |
| 1790636569 | 20 Pkt | 4 Pkt | 0 Pkt | 13.54 V | 0 DegC |
| 1790635931 | 13 Pkt | 4 Pkt | 1 Pkt | 13.48 V | 0 DegC |
| 1790634653 | 10 Pkt | 4 Pkt | 0 Pkt | 13.5 V | 0 DegC |
| 1790633377 | 8 Pkt | 4 Pkt | 0 Pkt | 13.48 V | 0 DegC |
| 1790632739 | 11 Pkt | 2 Pkt | 0 Pkt | 13.5 V | 0 DegC |
| 1790631472 | 15 Pkt | 4 Pkt | 0 Pkt | 13.5 V | 0 DegC |
| 1790630838 | 13 Pkt | 2 Pkt | 0 Pkt | 13.46 V | 0 DegC |
| 1790629558 | 17 Pkt | 2 Pkt | 0 Pkt | 13.46 V | 0 DegC |
| 1790628920 | 19 Pkt | 4 Pkt | 0 Pkt | 13.48 V | 0 DegC |
| 1790628281 | 22 Pkt | 5 Pkt | 0 Pkt | 13.5 V | 0 DegC |
| 1790627651 | 16 Pkt | 2 Pkt | 0 Pkt | 13.46 V | 0 DegC |
| 1790626370 | 18 Pkt | 2 Pkt | 0 Pkt | 13.5 V | 0 DegC |
| 1790625732 | 13 Pkt | 4 Pkt | 0 Pkt | 13.48 V | 0 DegC |
| 1790625105 | 15 Pkt | 4 Pkt | 0 Pkt | 13.5 V | 0 DegC |
| 1790624465 | 18 Pkt | 3 Pkt | 0 Pkt | 13.5 V | 0 DegC |
| 1790623826 | 19 Pkt | 4 Pkt | 0 Pkt | 13.46 V | 0 DegC |
| 1790623188 | 19 Pkt | 4 Pkt | 0 Pkt | 13.48 V | 0 DegC |
| 1790621914 | 20 Pkt | 13 Pkt | 0 Pkt | 13.5 V | 0 DegC |
| 1790620642 | 26 Pkt | 5 Pkt | 0 Pkt | 13.48 V | 0 DegC |
| 1790620003 | 35 Pkt | 4 Pkt | 0 Pkt | 13.48 V | 0 DegC |
*Used Equation Coefficients:
Rx10min: 0, 1, 0
Tx10min: 0, 1, 0
Digi10min: 0, 1, 0
Vbatt: 0, 0.02, 10
Tempre: 0, 0.5, -50
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)