This is the latest recevied telemetry packets stored in our database for station/object ED6YAE-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | DC* | RxP-1h* | Dg1h* | Eff1h* | DC-1* |
|---|---|---|---|---|---|
| 1786729426 | 9.08 Volt | 500 Pkt | 290 Pkt | 67 *100 | 0 Volt |
| 1786729126 | 9 Volt | 500 Pkt | 290 Pkt | 66 *100 | 0 Volt |
| 1786728826 | 9 Volt | 520 Pkt | 290 Pkt | 66 *100 | 0 Volt |
| 1786728526 | 9.08 Volt | 530 Pkt | 300 Pkt | 67 *100 | 0 Volt |
| 1786728226 | 9 Volt | 530 Pkt | 300 Pkt | 67 *100 | 0 Volt |
| 1786727926 | 9 Volt | 540 Pkt | 300 Pkt | 67 *100 | 0 Volt |
| 1786727626 | 9 Volt | 550 Pkt | 290 Pkt | 68 *100 | 0 Volt |
| 1786727326 | 9 Volt | 570 Pkt | 290 Pkt | 68 *100 | 0 Volt |
| 1786727026 | 9 Volt | 570 Pkt | 290 Pkt | 65 *100 | 0 Volt |
| 1786726726 | 9.08 Volt | 570 Pkt | 290 Pkt | 64 *100 | 0 Volt |
| 1786726426 | 9 Volt | 570 Pkt | 290 Pkt | 64 *100 | 0 Volt |
| 1786726126 | 9.08 Volt | 550 Pkt | 290 Pkt | 65 *100 | 0 Volt |
| 1786725826 | 9 Volt | 520 Pkt | 270 Pkt | 63 *100 | 0 Volt |
| 1786725526 | 9 Volt | 520 Pkt | 280 Pkt | 64 *100 | 0 Volt |
| 1786725226 | 9 Volt | 540 Pkt | 290 Pkt | 68 *100 | 0 Volt |
| 1786724926 | 9.15 Volt | 530 Pkt | 280 Pkt | 68 *100 | 0 Volt |
| 1786724626 | 9 Volt | 510 Pkt | 270 Pkt | 69 *100 | 0 Volt |
| 1786724326 | 9 Volt | 510 Pkt | 280 Pkt | 71 *100 | 0 Volt |
| 1786724026 | 9 Volt | 490 Pkt | 270 Pkt | 72 *100 | 0 Volt |
| 1786723726 | 9.15 Volt | 490 Pkt | 280 Pkt | 74 *100 | 0 Volt |
| 1786723426 | 9.08 Volt | 480 Pkt | 270 Pkt | 77 *100 | 0 Volt |
| 1786723126 | 9.08 Volt | 470 Pkt | 260 Pkt | 79 *100 | 0 Volt |
| 1786722826 | 9.08 Volt | 460 Pkt | 250 Pkt | 79 *100 | 0 Volt |
| 1786722526 | 9.08 Volt | 480 Pkt | 260 Pkt | 80 *100 | 0 Volt |
| 1786722226 | 9.15 Volt | 490 Pkt | 270 Pkt | 78 *100 | 0 Volt |
*Used Equation Coefficients:
DC: 0, 0.075, 0
RxP-1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
DC-1: 0, 0.075, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)