This is the latest recevied telemetry packets stored in our database for station/object YT6PT-8. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vin* | Rx1h* | Dg1h* | Eff1h* | Dg/Rx* |
|---|---|---|---|---|---|
| 1790654269 | 12.6 Volt | 280 Pkt | 40 Pkt | 78 % | 15.9 % |
| 1790653669 | 12.6 Volt | 280 Pkt | 40 Pkt | 81 % | 16.14 % |
| 1790653069 | 12.6 Volt | 290 Pkt | 40 Pkt | 82 % | 15.59 % |
| 1790652469 | 12.6 Volt | 290 Pkt | 40 Pkt | 83 % | 15.75 % |
| 1790651869 | 12.6 Volt | 290 Pkt | 40 Pkt | 83 % | 15.59 % |
| 1790651269 | 12.6 Volt | 290 Pkt | 40 Pkt | 83 % | 16.78 % |
| 1790650669 | 12.53 Volt | 290 Pkt | 50 Pkt | 84 % | 17.23 % |
| 1790650069 | 12.6 Volt | 280 Pkt | 50 Pkt | 86 % | 17.3 % |
| 1790649469 | 12.6 Volt | 290 Pkt | 40 Pkt | 87 % | 16.44 % |
| 1790648869 | 12.6 Volt | 290 Pkt | 50 Pkt | 87 % | 17.18 % |
| 1790648270 | 12.53 Volt | 260 Pkt | 50 Pkt | 87 % | 19.16 % |
| 1790647669 | 12.6 Volt | 230 Pkt | 40 Pkt | 86 % | 20.69 % |
| 1790647070 | 12.6 Volt | 190 Pkt | 40 Pkt | 83 % | 23.86 % |
| 1790646470 | 12.6 Volt | 160 Pkt | 40 Pkt | 79 % | 27.54 % |
| 1790645870 | 12.6 Volt | 140 Pkt | 40 Pkt | 76 % | 32.17 % |
| 1790645270 | 12.53 Volt | 120 Pkt | 40 Pkt | 72 % | 36.29 % |
| 1790644670 | 12.6 Volt | 110 Pkt | 40 Pkt | 70 % | 36.44 % |
| 1790644070 | 12.6 Volt | 100 Pkt | 40 Pkt | 67 % | 38.53 % |
| 1790643470 | 12.6 Volt | 110 Pkt | 40 Pkt | 71 % | 37.5 % |
| 1790642870 | 12.6 Volt | 110 Pkt | 40 Pkt | 70 % | 36.21 % |
| 1790642270 | 12.6 Volt | 110 Pkt | 40 Pkt | 71 % | 36.84 % |
| 1790641670 | 12.6 Volt | 100 Pkt | 40 Pkt | 74 % | 38.53 % |
| 1790641070 | 12.6 Volt | 100 Pkt | 40 Pkt | 76 % | 39.45 % |
| 1790640470 | 12.6 Volt | 100 Pkt | 40 Pkt | 75 % | 38.53 % |
| 1790639870 | 12.6 Volt | 110 Pkt | 40 Pkt | 75 % | 35.9 % |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Dg/Rx: 0, 0.001, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)