This is the latest recevied telemetry packets stored in our database for station/object M0UPS-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | BattSOC* | Volt* | Curr* | Rad* | CPM* |
|---|---|---|---|---|---|
| 1792144503 | 81 % | 13.2 V | 2 A | 9 uR/h | 16 CPM |
| 1792144204 | 81 % | 13.2 V | 1.5 A | 13 uR/h | 22 CPM |
| 1792143903 | 81 % | 13.2 V | 2 A | 7 uR/h | 13 CPM |
| 1792143603 | 81 % | 13.3 V | 3 A | 10 uR/h | 17 CPM |
| 1792143303 | 80 % | 13.1 V | 2 A | 14 uR/h | 24 CPM |
| 1792143003 | 80 % | 12.9 V | 0.5 A | 7 uR/h | 13 CPM |
| 1792142703 | 80 % | 12.9 V | 0.5 A | 11 uR/h | 20 CPM |
| 1792142403 | 80 % | 13 V | 1 A | 8 uR/h | 14 CPM |
| 1792142103 | 80 % | 13 V | 1 A | 7 uR/h | 12 CPM |
| 1792141803 | 80 % | 12.9 V | 1 A | 10 uR/h | 17 CPM |
| 1792141503 | 80 % | 12.9 V | 0.5 A | 8 uR/h | 14 CPM |
*Used Equation Coefficients:
BattSOC: 0, 1, 0
Volt: 0, 0.1, 0
Curr: 0, 0.5, -50
Rad: 0, 1, 0
CPM: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)