This is the latest recevied telemetry packets stored in our database for station/object XE1RCU-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vin* | Rx1h* | Dg1h* | Eff1h* | A5* |
|---|---|---|---|---|---|
| 1786730089 | 13.95 Volt | 30 Pkt | 0 Pkt | 91 Pcnt | 0 None |
| 1786726489 | 13.95 Volt | 0 Pkt | 0 Pkt | 54 Pcnt | 0 None |
| 1786722889 | 13.95 Volt | 0 Pkt | 0 Pkt | 15 Pcnt | 0 None |
| 1786719290 | 13.95 Volt | 10 Pkt | 0 Pkt | 57 Pcnt | 0 None |
| 1786715690 | 13.95 Volt | 0 Pkt | 0 Pkt | 37 Pcnt | 0 None |
| 1786712090 | 13.95 Volt | 10 Pkt | 0 Pkt | 65 Pcnt | 0 None |
| 1786708490 | 13.95 Volt | 10 Pkt | 0 Pkt | 68 Pcnt | 0 None |
| 1786704890 | 13.95 Volt | 0 Pkt | 0 Pkt | 53 Pcnt | 0 None |
| 1786701290 | 13.95 Volt | 0 Pkt | 0 Pkt | 52 Pcnt | 0 None |
| 1786697690 | 13.95 Volt | 0 Pkt | 0 Pkt | 53 Pcnt | 0 None |
| 1786694090 | 13.95 Volt | 0 Pkt | 0 Pkt | 60 Pcnt | 0 None |
| 1786690490 | 13.95 Volt | 10 Pkt | 0 Pkt | 83 Pcnt | 0 None |
| 1786686891 | 13.95 Volt | 10 Pkt | 0 Pkt | 76 Pcnt | 0 None |
| 1786683291 | 13.95 Volt | 10 Pkt | 0 Pkt | 62 Pcnt | 0 None |
| 1786679691 | 13.95 Volt | 0 Pkt | 0 Pkt | 69 Pcnt | 0 None |
| 1786676091 | 13.95 Volt | 10 Pkt | 0 Pkt | 70 Pcnt | 0 None |
| 1786672511 | 13.95 Volt | 10 Pkt | 0 Pkt | 62 Pcnt | 0 None |
| 1786668891 | 13.95 Volt | 10 Pkt | 0 Pkt | 69 Pcnt | 0 None |
| 1786665291 | 13.95 Volt | 50 Pkt | 0 Pkt | 91 Pcnt | 0 None |
| 1786661691 | 13.95 Volt | 80 Pkt | 0 Pkt | 86 Pcnt | 0 None |
| 1786658091 | 13.95 Volt | 120 Pkt | 0 Pkt | 95 Pcnt | 0 None |
| 1786654492 | 13.95 Volt | 120 Pkt | 0 Pkt | 96 Pcnt | 0 None |
| 1786650892 | 13.95 Volt | 20 Pkt | 0 Pkt | 92 Pcnt | 0 None |
| 1786647292 | 13.95 Volt | 70 Pkt | 0 Pkt | 95 Pcnt | 0 None |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
A5: 0, 0, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)