This is the latest recevied telemetry packets stored in our database for station/object XE2J-2. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vin* | Rx1h* | Dg1h* | Eff1h* | Temp* |
|---|---|---|---|---|---|
| 1790653082 | 12.53 Volt | 50 Pkt | 30 Pkt | 61 Pcnt | 25.5 C |
| 1790652182 | 12.53 Volt | 40 Pkt | 20 Pkt | 54 Pcnt | 25.5 C |
| 1790651282 | 12.53 Volt | 50 Pkt | 30 Pkt | 55 Pcnt | 26 C |
| 1790650382 | 12.6 Volt | 50 Pkt | 30 Pkt | 53 Pcnt | 26 C |
| 1790649482 | 12.6 Volt | 50 Pkt | 30 Pkt | 53 Pcnt | 26.5 C |
| 1790648582 | 12.6 Volt | 60 Pkt | 30 Pkt | 56 Pcnt | 26.5 C |
| 1790647682 | 12.6 Volt | 60 Pkt | 30 Pkt | 59 Pcnt | 27 C |
| 1790646782 | 12.68 Volt | 50 Pkt | 30 Pkt | 56 Pcnt | 27.5 C |
| 1790645882 | 12.68 Volt | 50 Pkt | 30 Pkt | 56 Pcnt | 28 C |
| 1790644982 | 12.68 Volt | 50 Pkt | 30 Pkt | 55 Pcnt | 28.5 C |
| 1790644082 | 12.68 Volt | 60 Pkt | 40 Pkt | 56 Pcnt | 29.5 C |
| 1790643182 | 12.68 Volt | 70 Pkt | 40 Pkt | 57 Pcnt | 30.5 C |
| 1790642282 | 12.68 Volt | 80 Pkt | 50 Pkt | 58 Pcnt | 31.5 C |
| 1790641382 | 12.68 Volt | 70 Pkt | 40 Pkt | 50 Pcnt | 33 C |
| 1790640482 | 12.75 Volt | 60 Pkt | 40 Pkt | 44 Pcnt | 34.5 C |
| 1790639582 | 12.68 Volt | 60 Pkt | 30 Pkt | 39 Pcnt | 36.5 C |
| 1790638682 | 12.75 Volt | 50 Pkt | 30 Pkt | 35 Pcnt | 38.5 C |
| 1790637782 | 12.9 Volt | 50 Pkt | 30 Pkt | 36 Pcnt | 41 C |
| 1790636882 | 13.13 Volt | 60 Pkt | 30 Pkt | 40 Pcnt | 43.5 C |
| 1790635982 | 13.13 Volt | 60 Pkt | 30 Pkt | 41 Pcnt | 46 C |
| 1790635082 | 13.13 Volt | 70 Pkt | 40 Pkt | 41 Pcnt | 46 C |
| 1790634183 | 13.13 Volt | 70 Pkt | 40 Pkt | 43 Pcnt | 44.5 C |
| 1790633283 | 13.13 Volt | 70 Pkt | 40 Pkt | 44 Pcnt | 42.5 C |
| 1790632383 | 13.13 Volt | 60 Pkt | 40 Pkt | 40 Pcnt | 40.5 C |
| 1790631483 | 13.05 Volt | 60 Pkt | 30 Pkt | 37 Pcnt | 39 C |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Temp: 0, 0.5, -64
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)