This is the latest recevied telemetry packets stored in our database for station/object SQ9SXN-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1778021461 | 723 Count | 389 Count | 387 Count | 0 VDC | 0 VDC |
| 1778019661 | 721 Count | 389 Count | 387 Count | 0 VDC | 0 VDC |
| 1778017860 | 720 Count | 389 Count | 387 Count | 0 VDC | 0 VDC |
| 1778016065 | 718 Count | 389 Count | 387 Count | 0 VDC | 0 VDC |
| 1778014259 | 717 Count | 389 Count | 387 Count | 0 VDC | 0 VDC |
| 1778012458 | 705 Count | 379 Count | 377 Count | 0 VDC | 0 VDC |
| 1778010657 | 675 Count | 350 Count | 348 Count | 0 VDC | 0 VDC |
| 1778008856 | 645 Count | 322 Count | 320 Count | 0 VDC | 0 VDC |
| 1778007056 | 625 Count | 303 Count | 301 Count | 0 VDC | 0 VDC |
| 1778005262 | 620 Count | 300 Count | 298 Count | 0 VDC | 0 VDC |
| 1778003462 | 591 Count | 272 Count | 270 Count | 0 VDC | 0 VDC |
| 1778001661 | 585 Count | 268 Count | 266 Count | 0 VDC | 0 VDC |
| 1777999860 | 584 Count | 268 Count | 266 Count | 0 VDC | 0 VDC |
| 1777998059 | 582 Count | 268 Count | 266 Count | 0 VDC | 0 VDC |
| 1777996258 | 581 Count | 268 Count | 266 Count | 0 VDC | 0 VDC |
| 1777994458 | 579 Count | 268 Count | 266 Count | 0 VDC | 0 VDC |
| 1777992657 | 578 Count | 268 Count | 266 Count | 0 VDC | 0 VDC |
| 1777990856 | 561 Count | 253 Count | 251 Count | 0 VDC | 0 VDC |
| 1777989055 | 530 Count | 223 Count | 221 Count | 0 VDC | 0 VDC |
| 1777987255 | 499 Count | 194 Count | 192 Count | 0 VDC | 0 VDC |
| 1777985454 | 469 Count | 165 Count | 163 Count | 0 VDC | 0 VDC |
| 1777984745 | 468 Count | 165 Count | 163 Count | 0 VDC | 0 VDC |
| 1777982945 | 467 Count | 165 Count | 163 Count | 0 VDC | 0 VDC |
| 1777981144 | 465 Count | 165 Count | 163 Count | 0 VDC | 0 VDC |
| 1777979343 | 464 Count | 165 Count | 163 Count | 0 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)