This is the latest recevied telemetry packets stored in our database for station/object VK8ZM-6. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Temp* | Vin* | Rx1h* | Dg1h* | Eff1h* |
|---|---|---|---|---|---|
| 1836274804 | 79.7 F | 13.43 Volt | 0 Pkt | 0 Pkt | 0 Pcnt |
| 1836274444 | 78.8 F | 13.65 Volt | 0 Pkt | 0 Pkt | 0 Pcnt |
| 1836274418 | 80.6 F | 13.65 Volt | 0 Pkt | 0 Pkt | 0 Pcnt |
| 1836274084 | 77.9 F | 13.35 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763708723 | 119.3 F | 13.43 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763708363 | 118.4 F | 13.5 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763708003 | 118.4 F | 13.5 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763707643 | 118.4 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763707283 | 117.5 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763706923 | 118.4 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763706563 | 118.4 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763706203 | 118.4 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763705843 | 119.3 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763705483 | 118.4 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763705123 | 118.4 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763704763 | 119.3 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763704403 | 119.3 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763704043 | 119.3 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763703683 | 118.4 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763703323 | 117.5 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763702963 | 117.5 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763702603 | 116.6 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763702243 | 116.6 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763701883 | 116.6 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
| 1763701523 | 117.5 F | 14.25 Volt | 0 Pkt | 0 Pkt | 100 Pcnt |
*Used Equation Coefficients:
Temp: 0, 0.9, -83.2
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)