This is the latest recevied telemetry packets stored in our database for station/object SA5VCC-15. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | VBat* | Bat* | CpuTemp* | CpuHum* | Lux* |
|---|---|---|---|---|---|
| 1786723832 | 4.33 V | 20 C | 27.6 C | 67.8 % | 0 lx |
| 1786721288 | 4.31 V | 19.9 C | 26.8 C | 69.1 % | 0 lx |
| 1786717472 | 4.32 V | 20.8 C | 31.8 C | 67.9 % | 0 lx |
| 1786712384 | 4.34 V | 20.5 C | 31.5 C | 67.8 % | 0 lx |
| 1786709840 | 4.33 V | 20.6 C | 29.8 C | 68.9 % | 0 lx |
| 1786708568 | 4.32 V | 20.4 C | 29.9 C | 69.2 % | 0 lx |
| 1786707296 | 4.37 V | 20.4 C | 30.4 C | 69.1 % | 0 lx |
| 1786706024 | 4.37 V | 20 C | 33.6 C | 68.3 % | 0 lx |
| 1786704752 | 4.44 V | 19.8 C | 42.6 C | 63.1 % | 0 lx |
| 1786702208 | 4.37 V | 19.3 C | 39 C | 64.5 % | 0 lx |
| 1786698391 | 4.32 V | 19.1 C | 27.2 C | 68.6 % | 0 lx |
| 1786684399 | 4.35 V | 18.6 C | 19.2 C | 69.6 % | 0 lx |
| 1786680583 | 4.32 V | 18.6 C | 14.8 C | 69.5 % | 0 lx |
| 1786678039 | 4.31 V | 18.7 C | 13.8 C | 69.4 % | 0 lx |
| 1786671679 | 4.31 V | 18.8 C | 14.7 C | 70 % | 0 lx |
| 1786670407 | 4.3 V | 18.8 C | 14.6 C | 69.9 % | 0 lx |
| 1786669135 | 4.31 V | 18.9 C | 14.8 C | 69.8 % | 0 lx |
| 1786666590 | 4.31 V | 18.9 C | 15.4 C | 69.9 % | 0 lx |
| 1786662774 | 4.31 V | 19.1 C | 15.2 C | 70.1 % | 0 lx |
| 1786657689 | 4.3 V | 19.3 C | 15.8 C | 69.9 % | 0 lx |
| 1786652598 | 4.3 V | 19.5 C | 17.7 C | 70.3 % | 0 lx |
| 1786650054 | 4.31 V | 19.6 C | 18.8 C | 70.4 % | 0 lx |
| 1786648782 | 4.3 V | 19.8 C | 19.7 C | 70.4 % | 0 lx |
| 1786646238 | 4.29 V | 19.9 C | 23.4 C | 69.4 % | 0 lx |
*Used Equation Coefficients:
VBat: 0, 0.01, 2.5
Bat: 0, 0.1, 0
CpuTemp: 0, 0.1, 0
CpuHum: 0, 0.1, 0
Lux: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)