This is the latest recevied telemetry packets stored in our database for station/object W2KGY-2. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | VBat* | VSolar* | VLight* | CPUTemp* | CPULoad* |
|---|---|---|---|---|---|
| 1778043203 | 25.5 | 0 | 12.2 | 40.8 | 0.02 |
| 1778041401 | 25.5 | 0 | 12.2 | 40.8 | 0 |
| 1778039599 | 25.6 | 0 | 12.2 | 41.3 | 0.02 |
| 1778034194 | 25.7 | 0 | 12.2 | 42.4 | 0 |
| 1778026986 | 25.8 | 3.9 | 12.2 | 44 | 0 |
| 1778026625 | 25.8 | 9.3 | 12.2 | 44 | 0 |
| 1778026324 | 25.8 | 14.4 | 12.2 | 44 | 0 |
| 1778026267 | 26 | 15.5 | 0 | 44 | 0 |
| 1778025903 | 26 | 20.8 | 0 | 44 | 0 |
| 1778022661 | 26.1 | 29.3 | 0 | 45.6 | 0 |
| 1778020858 | 26.5 | 28.5 | 0 | 46.7 | 0 |
| 1778019057 | 26.3 | 32.4 | 0 | 47.8 | 0 |
| 1778015452 | 27.6 | 33.8 | 0 | 52.1 | 0 |
| 1778013650 | 27.6 | 34.4 | 0 | 53.2 | 0 |
| 1778011810 | 27.6 | 32 | 0 | 53.7 | 0 |
| 1778010008 | 27.6 | 32.6 | 0 | 53.2 | 0 |
| 1778008207 | 27.6 | 33.2 | 0 | 53.2 | 0.01 |
| 1778006405 | 28.8 | 34.5 | 0 | 54.8 | 0 |
| 1778000999 | 28.7 | 33.7 | 0 | 58 | 0 |
| 1777999197 | 27.5 | 32.6 | 0 | 56.9 | 0 |
| 1777997396 | 27.6 | 32.7 | 0 | 55.8 | 0 |
| 1777995596 | 27.6 | 32.5 | 0 | 54.8 | 0 |
| 1777990189 | 29 | 33.7 | 0 | 48.3 | 0 |
| 1777988386 | 29 | 33 | 0 | 46.2 | 0 |
| 1777986585 | 29.1 | 32.7 | 0 | 42.4 | 0 |
*Used Equation Coefficients:
VBat: 0, 1, 0
VSolar: 0, 1, 0
VLight: 0, 1, 0
CPUTemp: 0, 1, 0
CPULoad: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)