This is the latest recevied telemetry packets stored in our database for station/object MB7UAL. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Vin* | Rx1h* | Dg1h* | Eff1h* | CabT* |
---|---|---|---|---|---|
1732468117 | 13.88 Volt | 360 Pkt | 60 Pkt | 98 Pcnt | 157 c |
1732467217 | 13.88 Volt | 360 Pkt | 60 Pkt | 98 Pcnt | 157 c |
1732466317 | 13.88 Volt | 320 Pkt | 40 Pkt | 98 Pcnt | 158 c |
1732465417 | 13.88 Volt | 270 Pkt | 10 Pkt | 99 Pcnt | 158 c |
1732464517 | 13.88 Volt | 240 Pkt | 0 Pkt | 99 Pcnt | 158 c |
1732463617 | 13.88 Volt | 240 Pkt | 0 Pkt | 99 Pcnt | 158 c |
1732462717 | 13.88 Volt | 240 Pkt | 0 Pkt | 99 Pcnt | 158 c |
1732461817 | 13.88 Volt | 240 Pkt | 0 Pkt | 98 Pcnt | 158 c |
1732460917 | 13.88 Volt | 250 Pkt | 0 Pkt | 98 Pcnt | 158 c |
1732460017 | 13.88 Volt | 240 Pkt | 0 Pkt | 98 Pcnt | 158 c |
1732459117 | 13.88 Volt | 250 Pkt | 0 Pkt | 98 Pcnt | 158 c |
1732458217 | 13.88 Volt | 260 Pkt | 0 Pkt | 100 Pcnt | 159 c |
1732457317 | 13.88 Volt | 260 Pkt | 10 Pkt | 96 Pcnt | 159 c |
1732456417 | 13.88 Volt | 260 Pkt | 10 Pkt | 95 Pcnt | 159 c |
1732455517 | 13.88 Volt | 260 Pkt | 0 Pkt | 93 Pcnt | 159 c |
1732454617 | 13.88 Volt | 250 Pkt | 0 Pkt | 93 Pcnt | 159 c |
1732453717 | 13.88 Volt | 250 Pkt | 0 Pkt | 96 Pcnt | 160 c |
1732452817 | 13.88 Volt | 240 Pkt | 0 Pkt | 98 Pcnt | 160 c |
1732451917 | 13.88 Volt | 250 Pkt | 0 Pkt | 98 Pcnt | 161 c |
1732451017 | 13.88 Volt | 250 Pkt | 0 Pkt | 97 Pcnt | 161 c |
1732450117 | 13.88 Volt | 260 Pkt | 10 Pkt | 97 Pcnt | 161 c |
1732449217 | 13.88 Volt | 260 Pkt | 0 Pkt | 97 Pcnt | 162 c |
1732448317 | 13.88 Volt | 270 Pkt | 10 Pkt | 97 Pcnt | 162 c |
1732447417 | 13.88 Volt | 270 Pkt | 10 Pkt | 96 Pcnt | 163 c |
1732446517 | 13.88 Volt | 270 Pkt | 10 Pkt | 96 Pcnt | 164 c |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
CabT: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)