This is the latest recevied telemetry packets stored in our database for station/object VK4RAR-3. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | BATT V* | Temp 1* | Temp 2* | Spam* | DcoEf* |
---|---|---|---|---|---|
1732226678 | 13.65 Volt | 21 C | 22 C | 54 Pakts | 46 Pakts |
1732226378 | 13.58 Volt | 21 C | 22 C | 58 Pakts | 46 Pakts |
1732226078 | 13.43 Volt | 20.5 C | 21.5 C | 31 Pakts | 42 Pakts |
1732225778 | 13.65 Volt | 20.5 C | 21.5 C | 28 Pakts | 43 Pakts |
1732225478 | 13.65 Volt | 20.5 C | 21.5 C | 39 Pakts | 43 Pakts |
1732225178 | 13.65 Volt | 20.5 C | 21.5 C | 49 Pakts | 42 Pakts |
1732224878 | 13.65 Volt | 20.5 C | 21.5 C | 31 Pakts | 41 Pakts |
1732224578 | 13.65 Volt | 20.5 C | 21.5 C | 36 Pakts | 44 Pakts |
1732224278 | 13.58 Volt | 20.5 C | 21.5 C | 24 Pakts | 46 Pakts |
1732223678 | 12.23 Volt | 20.5 C | 21.5 C | 8 Pakts | 51 Pakts |
1732223378 | 12.3 Volt | 20.5 C | 21.5 C | 32 Pakts | 55 Pakts |
1732223078 | 13.65 Volt | 20.5 C | 21.5 C | 28 Pakts | 58 Pakts |
1732222778 | 13.65 Volt | 20.5 C | 21.5 C | 37 Pakts | 59 Pakts |
1732222478 | 13.65 Volt | 20.5 C | 21.5 C | 30 Pakts | 61 Pakts |
1732222178 | 13.65 Volt | 20.5 C | 21.5 C | 26 Pakts | 62 Pakts |
1732221878 | 12.98 Volt | 20.5 C | 21.5 C | 33 Pakts | 63 Pakts |
1732221578 | 12.3 Volt | 20 C | 21 C | 50 Pakts | 66 Pakts |
1732221278 | 13.65 Volt | 20 C | 21 C | 54 Pakts | 68 Pakts |
1732220978 | 13.65 Volt | 20 C | 21 C | 45 Pakts | 68 Pakts |
1732220678 | 13.65 Volt | 20 C | 21 C | 44 Pakts | 68 Pakts |
1732220378 | 13.65 Volt | 20 C | 21 C | 47 Pakts | 68 Pakts |
1732220078 | 13.65 Volt | 20 C | 21 C | 44 Pakts | 70 Pakts |
1732219778 | 13.65 Volt | 20 C | 21 C | 47 Pakts | 71 Pakts |
1732219478 | 13.58 Volt | 20 C | 21 C | 34 Pakts | 71 Pakts |
1732219178 | 13.65 Volt | 20 C | 21 C | 43 Pakts | 71 Pakts |
*Used Equation Coefficients:
BATT V: 0, 0.075, 0
Temp 1: 0, 0.5, -64
Temp 2: 0, 0.5, -64
Spam: 0, 1, 0
DcoEf: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)