This is the latest recevied telemetry packets stored in our database for station/object SP9MOA-6. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Battery* | T_in* | T_out* | Rx1h* | Dg1h* |
|---|---|---|---|---|---|
| 1778030611 | 14 Volt | 22.5 C | 17.5 C | 220 Pkt | 10 Pkt |
| 1778030011 | 14 Volt | 22.5 C | 18 C | 210 Pkt | 10 Pkt |
| 1778029411 | 14 Volt | 22.5 C | 17.5 C | 210 Pkt | 10 Pkt |
| 1778028811 | 14 Volt | 22 C | 17.5 C | 200 Pkt | 10 Pkt |
| 1778028211 | 14 Volt | 22 C | 17.5 C | 200 Pkt | 10 Pkt |
| 1778027611 | 14 Volt | 22 C | 17 C | 190 Pkt | 10 Pkt |
| 1778027011 | 14 Volt | 22.5 C | 17.5 C | 190 Pkt | 10 Pkt |
| 1778026411 | 14 Volt | 22.5 C | 18 C | 170 Pkt | 10 Pkt |
| 1778025811 | 14 Volt | 22.5 C | 18 C | 180 Pkt | 10 Pkt |
| 1778025211 | 14 Volt | 22.5 C | 18 C | 190 Pkt | 10 Pkt |
| 1778024612 | 14 Volt | 22.5 C | 17.5 C | 200 Pkt | 10 Pkt |
| 1778024012 | 14 Volt | 22.5 C | 17.5 C | 190 Pkt | 10 Pkt |
| 1778023415 | 14 Volt | 23 C | 18 C | 180 Pkt | 10 Pkt |
| 1778022816 | 14 Volt | 23 C | 18.5 C | 180 Pkt | 10 Pkt |
| 1778022212 | 13.9 Volt | 23 C | 18.5 C | 180 Pkt | 10 Pkt |
| 1778021612 | 13.9 Volt | 23.5 C | 18.5 C | 170 Pkt | 10 Pkt |
| 1778021012 | 13.9 Volt | 23.5 C | 18.5 C | 150 Pkt | 10 Pkt |
| 1778020412 | 13.9 Volt | 23.5 C | 19 C | 160 Pkt | 10 Pkt |
| 1778019812 | 14 Volt | 23.5 C | 19 C | 160 Pkt | 10 Pkt |
| 1778019212 | 14 Volt | 23.5 C | 19 C | 170 Pkt | 10 Pkt |
| 1778018613 | 13.9 Volt | 24 C | 19 C | 170 Pkt | 0 Pkt |
| 1778018012 | 13.9 Volt | 24 C | 19 C | 170 Pkt | 0 Pkt |
| 1778017415 | 13.9 Volt | 24.5 C | 19 C | 170 Pkt | 0 Pkt |
| 1778016812 | 13.9 Volt | 25 C | 20 C | 160 Pkt | 0 Pkt |
| 1778016212 | 13.9 Volt | 25 C | 20.5 C | 160 Pkt | 0 Pkt |
*Used Equation Coefficients:
Battery: 0, 0.1, 0
T_in: 0, 0.5, -64
T_out: 0, 0.5, -64
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)