This is the latest recevied telemetry packets stored in our database for station/object PP1GEC-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vin* | Rx1h* | Value3* | Value4* | Value5* |
|---|---|---|---|---|---|
| 1766300785 | 14.38 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766297181 | 14.38 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766293577 | 14.46 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766289974 | 14.46 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766286370 | 14.46 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766282767 | 14.46 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766279163 | 14.38 Volt | 10 Pkt | 0 | 0 | 0 |
| 1766275560 | 14.46 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766271956 | 14.38 Volt | 10 Pkt | 0 | 0 | 0 |
| 1766268353 | 14.38 Volt | 10 Pkt | 0 | 0 | 0 |
| 1766264750 | 14.38 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766261146 | 14.38 Volt | 10 Pkt | 0 | 0 | 0 |
| 1766257542 | 14.46 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766253939 | 14.38 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766250335 | 14.38 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766246731 | 14.38 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766243128 | 14.46 Volt | 10 Pkt | 0 | 0 | 0 |
| 1766239524 | 14.38 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766235921 | 14.46 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766232317 | 14.38 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766228714 | 14.46 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766225110 | 14.46 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766221507 | 14.38 Volt | 20 Pkt | 0 | 0 | 0 |
| 1766217903 | 14.38 Volt | 20 Pkt | 0 | 0 | 0 |
*Used Equation Coefficients:
Vin: 0, 0.079, 0
Rx1h: 0, 10, 0
Value3: 0, 0, 0
Value4: 0, 0, 0
Value5: 0, 0, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)