This is the latest recevied telemetry packets stored in our database for station/object SM0PQB-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vin* | Temp* | Temp2* | Rx10m* | Eff1h* |
|---|---|---|---|---|---|
| 1836274621 | 12.23 Volt | 32.5 C | 0 C | 0 Pkt | 100 % |
| 1836274471 | 12.3 Volt | 32.5 C | 0 C | 0 Pkt | 100 % |
| 1836274321 | 12.23 Volt | 32.5 C | 0 C | 0 Pkt | 100 % |
| 1836274171 | 12.23 Volt | 32.5 C | 0 C | 0 Pkt | 100 % |
| 1836274021 | 12.23 Volt | 32.5 C | 0 C | 0 Pkt | 100 % |
| 1762326422 | 12 Volt | 28 C | 0 C | 1 Pkt | 100 % |
| 1762326122 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762325822 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762325522 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762325222 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762324922 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762324622 | 12 Volt | 28 C | 0 C | 1 Pkt | 100 % |
| 1762324322 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762324022 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762323722 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762323422 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762323122 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762322822 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762322522 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762322222 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762321922 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762321622 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762321322 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762321022 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
| 1762320722 | 12 Volt | 28 C | 0 C | 0 Pkt | 100 % |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Temp: 0, 0.5, -64
Temp2: 0, 0.5, -64
Rx10m: 0, 1, 0
Eff1h: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)