Time | RxTraffic* | TxTraffic* | RxDrop* | RSSI* | Voltage* |
---|---|---|---|---|---|
1754417340 | 2 Pkt | 0 Pkt | 5 Pkt | -76 dBm | 4.43 V |
1754415146 | 21 Pkt | 6 Pkt | 5 Pkt | -75 dBm | 4.35 V |
1754413911 | 12 Pkt | 1 Pkt | 1 Pkt | -72 dBm | 4.35 V |
1754412685 | 20 Pkt | 1 Pkt | 0 Pkt | -77 dBm | 4.43 V |
1754411455 | 1 Pkt | 0 Pkt | 0 Pkt | -81 dBm | 4.39 V |
1754407179 | 0 Pkt | 0 Pkt | 0 Pkt | -82 dBm | 4.47 V |
1754403048 | 1 Pkt | 0 Pkt | 8 Pkt | -72 dBm | 4.29 V |
1754402836 | 16 Pkt | 1 Pkt | 33 Pkt | -73 dBm | 4.31 V |
1754400959 | 0 Pkt | 0 Pkt | 1 Pkt | -71 dBm | 4.31 V |
1754400483 | 33 Pkt | 4 Pkt | 45 Pkt | -74 dBm | 4.29 V |
1754398289 | 2 Pkt | 0 Pkt | 10 Pkt | -69 dBm | 4.27 V |
1754397473 | 39 Pkt | 0 Pkt | 115 Pkt | -73 dBm | 4.29 V |
1754394002 | 0 Pkt | 0 Pkt | 7 Pkt | -74 dBm | 4.31 V |
1754393509 | 33 Pkt | 1 Pkt | 38 Pkt | -72 dBm | 4.29 V |
1754390637 | 6 Pkt | 0 Pkt | 4 Pkt | -75 dBm | 4.31 V |
1754390209 | 59 Pkt | 1 Pkt | 29 Pkt | -71 dBm | 4.31 V |
1754388383 | 1 Pkt | 1 Pkt | 4 Pkt | -72 dBm | 4.29 V |
1754386006 | 24 Pkt | 2 Pkt | 2 Pkt | -77 dBm | 4.31 V |
1754382322 | 13 Pkt | 2 Pkt | 0 Pkt | -76 dBm | 4.31 V |
1754381094 | 15 Pkt | 2 Pkt | 1 Pkt | -78 dBm | 4.29 V |
1754379865 | 16 Pkt | 1 Pkt | 1 Pkt | -76 dBm | 4.29 V |
1754378637 | 16 Pkt | 2 Pkt | 1 Pkt | -77 dBm | 4.31 V |
1754371275 | 15 Pkt | 1 Pkt | 0 Pkt | -80 dBm | 4.33 V |
1754370048 | 12 Pkt | 2 Pkt | 1 Pkt | -75 dBm | 4.33 V |
1754368822 | 17 Pkt | 2 Pkt | 0 Pkt | -78 dBm | 4.33 V |
*Used Equation Coefficients:
RxTraffic: 0, 1, 0
TxTraffic: 0, 1, 0
RxDrop: 0, 1, 0
RSSI: 0, -1, 0
Voltage: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)