This is the latest recevied telemetry packets stored in our database for station/object OE3PYC-7. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Celsius* | Rel_Hum* | Atm_Press* | Value4* | Value5* |
|---|---|---|---|---|---|
| 1778019914 | 21.7 C | 37.7 % | 1021.38 hPa | 0 | 0 |
| 1778015358 | 21.5 C | 38.32 % | 1022.38 hPa | 0 | 0 |
| 1778013073 | 21.5 C | 38.25 % | 1027 hPa | 0 | 0 |
| 1778008936 | 21.5 C | 38.54 % | 1021.13 hPa | 0 | 0 |
| 1778004708 | 21.4 C | 38.82 % | 1019.63 hPa | 0 | 0 |
| 1778001334 | 21.4 C | 38.72 % | 1019.88 hPa | 0 | 0 |
| 1777994231 | 21.5 C | 37.91 % | 1019 hPa | 0 | 0 |
| 1777986897 | 21.7 C | 37.13 % | 1019.25 hPa | 0 | 0 |
| 1777981612 | 21.5 C | 36.92 % | 1024.88 hPa | 0 | 0 |
| 1777978368 | 21.1 C | 36.52 % | 1018.88 hPa | 0 | 0 |
| 1777970624 | 21.5 C | 38.05 % | 1021.38 hPa | 0 | 0 |
| 1777964960 | 21.5 C | 38.65 % | 1022.75 hPa | 0 | 0 |
| 1777962020 | 21.4 C | 38.66 % | 1020.75 hPa | 0 | 0 |
| 1777957701 | 21.4 C | 38.44 % | 1020.88 hPa | 0 | 0 |
| 1777952969 | 21.4 C | 38.58 % | 1020.88 hPa | 0 | 0 |
| 1777946530 | 21.5 C | 38.45 % | 1020.5 hPa | 0 | 0 |
| 1777940285 | 21.6 C | 38.07 % | 1021 hPa | 0 | 0 |
| 1777938120 | 21.7 C | 38.22 % | 1029.75 hPa | 0 | 0 |
*Used Equation Coefficients:
Celsius: 0, 0.1, -50
Rel_Hum: 0, 0.01, 0
Atm_Press: 0, 0.125, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)