This is the latest recevied telemetry packets stored in our database for station/object XE2B-29. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Voltage* | Celsius* | Rel_Hum* | Atm_Press* | Value5* |
|---|---|---|---|---|---|
| 1790629851 | 4.04 VDC | 40.9 C | 31.11 % | 0 hPa | 0 |
| 1790628703 | 4.19 VDC | 40.3 C | 29.83 % | 0 hPa | 0 |
| 1790625245 | 4.19 VDC | 37.6 C | 25.54 % | 0 hPa | 0 |
| 1790624959 | 4.17 VDC | 37.3 C | 28.17 % | 0 hPa | 0 |
| 1790623350 | 4.12 VDC | 38.4 C | 25 % | 0 hPa | 0 |
| 1790622771 | 4.06 VDC | 39.3 C | 25.75 % | 0 hPa | 0 |
| 1790622442 | 4.03 VDC | 39.2 C | 31.53 % | 0 hPa | 0 |
| 1790621615 | 3.8 VDC | 39.3 C | 32.76 % | 0 hPa | 0 |
| 1790618658 | 4.04 VDC | 40.3 C | 26.42 % | 0 hPa | 0 |
| 1790617297 | 3.97 VDC | 41.4 C | 25.45 % | 0 hPa | 0 |
| 1790616860 | 3.92 VDC | 41.7 C | 29.34 % | 0 hPa | 0 |
| 1790616600 | 3.9 VDC | 41.9 C | 28.92 % | 0 hPa | 0 |
| 1790611648 | 3.8 VDC | 35 C | 38.91 % | 0 hPa | 0 |
| 1790607615 | 4.07 VDC | 26.9 C | 48.17 % | 0 hPa | 0 |
| 1790606977 | 4.05 VDC | 24.9 C | 50.74 % | 0 hPa | 0 |
| 1790606576 | 3.99 VDC | 22.6 C | 46.23 % | 817.88 hPa | 0 |
| 1790566303 | 3.84 VDC | 29 C | 38.67 % | 0 hPa | 0 |
| 1790557278 | 3.95 VDC | 31.8 C | 36.13 % | 0 hPa | 0 |
*Used Equation Coefficients:
Voltage: 0, 0.01, 0
Celsius: 0, 0.1, -50
Rel_Hum: 0, 0.01, 0
Atm_Press: 0, 0.125, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)