This is the latest recevied telemetry packets stored in our database for station/object LU2BFM-1. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | RxTraffic* | TxTraffic* | RxDrop* | RSSI* | Voltage* |
|---|---|---|---|---|---|
| 1774463180 | 8 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.56 V |
| 1774459557 | 8 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.58 V |
| 1774455934 | 8 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.58 V |
| 1774452311 | 5 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.58 V |
| 1774448687 | 6 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.58 V |
| 1774445066 | 5 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.6 V |
| 1774441442 | 0 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.6 V |
| 1774437820 | 0 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.6 V |
| 1774434198 | 3 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.62 V |
| 1774423329 | 8 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.62 V |
| 1774416083 | 4 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.6 V |
| 1774408838 | 6 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.6 V |
| 1774405214 | 6 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.58 V |
| 1774401553 | 6 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.6 V |
| 1774397930 | 8 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.54 V |
| 1774394307 | 8 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.6 V |
| 1774390685 | 6 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.52 V |
| 1774387061 | 5 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.56 V |
| 1774379816 | 6 Pkt | 0 Pkt | 0 Pkt | 31 dBm | 14.56 V |
*Used Equation Coefficients:
RxTraffic: 0, 1, 0
TxTraffic: 0, 1, 0
RxDrop: 0, 1, 0
RSSI: 0, -1, 0
Voltage: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)