This is the latest recevied telemetry packets stored in our database for station/object F4HVV-15. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Value1* | Value2* | Value3* | Value4* | Value5* |
---|---|---|---|---|---|
1750193053 | 13177 | 39 | 13467 | 65 | 26.58 |
1750193048 | 13522 | 38 | 17967 | 60 | 28.93 |
1750191559 | 13473 | 37 | 19263 | 55 | 32.05 |
1750191555 | 13413 | 37 | 19790 | 54 | 34.4 |
1750191552 | 13389 | 38 | 20153 | 53 | 35.08 |
1750191548 | 13395 | 33 | 20389 | 50 | 35.6 |
1750172270 | 13528 | 37 | 21915 | 49 | 31.88 |
1750172266 | 13522 | 82 | 21861 | 79 | 31.38 |
1750172262 | 13534 | 37 | 21964 | 48 | 30.85 |
1750172258 | 13595 | 37 | 22285 | 54 | 27.15 |
1750172255 | 13637 | 38 | 22115 | 90 | 24.85 |
1750172251 | 13661 | 37 | 22133 | 98 | 24.08 |
1750169451 | 13679 | 37 | 22048 | 130 | 22.93 |
1750169448 | 13685 | 37 | 22024 | 151 | 22.08 |
1750168349 | 14775 | 32 | 21134 | 300 | 21.28 |
1750168345 | 13976 | 89 | 20486 | 276 | 19.68 |
1750153441 | 13776 | 36 | 20165 | 232 | 18.6 |
1750153437 | 13570 | 34 | 17791 | 192 | 17.48 |
1750149661 | 13504 | 35 | 19814 | 166 | 15.83 |
1750147952 | 13031 | 38 | 16386 | 92 | 13.88 |
1750146518 | 12959 | 37 | 16259 | 81 | 13.55 |
1750142488 | 12868 | 97 | 15714 | 74 | 13.28 |
1750142333 | 12868 | 38 | 14297 | 71 | 12.95 |
1750141588 | 12838 | 39 | 14000 | 67 | 12.73 |
1750140701 | 12807 | 38 | 13104 | 61 | 12.55 |
*Used Equation Coefficients:
Value1: 0, 1, 0
Value2: 0, 1, 0
Value3: 0, 1, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)