This is the latest recevied telemetry packets stored in our database for station/object DB0TIT-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vin* | Rx1h* | Dg1h* | Eff1h* | Effto* |
|---|---|---|---|---|---|
| 1762344336 | 13.9 Volt | 820 Pkt | 170 Pkt | 50 Pcnt | 0 None |
| 1762340736 | 13.9 Volt | 310 Pkt | 90 Pkt | 50 Pcnt | 0 None |
| 1762337136 | 13.9 Volt | 530 Pkt | 110 Pkt | 50 Pcnt | 0 None |
| 1762333537 | 13.9 Volt | 830 Pkt | 150 Pkt | 50 Pcnt | 0 None |
| 1762329937 | 13.9 Volt | 810 Pkt | 150 Pkt | 50 Pcnt | 0 None |
| 1762326337 | 13.9 Volt | 740 Pkt | 130 Pkt | 50 Pcnt | 0 None |
| 1762322737 | 13.9 Volt | 800 Pkt | 130 Pkt | 50 Pcnt | 0 None |
| 1762319137 | 13.9 Volt | 830 Pkt | 140 Pkt | 50 Pcnt | 0 None |
| 1762315538 | 13.9 Volt | 880 Pkt | 170 Pkt | 50 Pcnt | 0 None |
| 1762311940 | 13.9 Volt | 810 Pkt | 200 Pkt | 50 Pcnt | 0 None |
| 1762308338 | 13.9 Volt | 700 Pkt | 240 Pkt | 50 Pcnt | 0 None |
| 1762304738 | 13.9 Volt | 740 Pkt | 200 Pkt | 50 Pcnt | 0 None |
| 1762301139 | 13.9 Volt | 780 Pkt | 190 Pkt | 50 Pcnt | 0 None |
| 1762297539 | 13.9 Volt | 830 Pkt | 160 Pkt | 50 Pcnt | 0 None |
| 1762293939 | 13.9 Volt | 810 Pkt | 140 Pkt | 50 Pcnt | 0 None |
| 1762290339 | 13.9 Volt | 850 Pkt | 150 Pkt | 50 Pcnt | 0 None |
| 1762286740 | 13.9 Volt | 760 Pkt | 160 Pkt | 50 Pcnt | 0 None |
| 1762283139 | 13.9 Volt | 530 Pkt | 150 Pkt | 50 Pcnt | 0 None |
| 1762279540 | 13.9 Volt | 650 Pkt | 200 Pkt | 50 Pcnt | 0 None |
| 1762275940 | 13.9 Volt | 660 Pkt | 180 Pkt | 50 Pcnt | 0 None |
| 1762272340 | 13.9 Volt | 560 Pkt | 170 Pkt | 50 Pcnt | 0 None |
| 1762268740 | 13.9 Volt | 690 Pkt | 190 Pkt | 50 Pcnt | 0 None |
| 1762265140 | 13.9 Volt | 820 Pkt | 170 Pkt | 50 Pcnt | 0 None |
| 1762261542 | 13.9 Volt | 660 Pkt | 120 Pkt | 50 Pcnt | 0 None |
*Used Equation Coefficients:
Vin: 0, 0.079, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Effto: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)