This is the latest recevied telemetry packets stored in our database for station/object SA7NOA-1. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1792150900 | 0 Count | 15 Count | 0 Count | 4.07 VDC | 0 VDC |
| 1792149996 | 242 Count | 1020 Count | 0 Count | 4.08 VDC | 0 VDC |
| 1792149093 | 241 Count | 1000 Count | 0 Count | 4.07 VDC | 0 VDC |
| 1792148189 | 240 Count | 989 Count | 0 Count | 4.07 VDC | 0 VDC |
| 1792147286 | 239 Count | 974 Count | 0 Count | 4.07 VDC | 0 VDC |
| 1792146382 | 238 Count | 956 Count | 0 Count | 4.07 VDC | 0 VDC |
| 1792145479 | 237 Count | 935 Count | 0 Count | 4.07 VDC | 0 VDC |
| 1792144575 | 236 Count | 916 Count | 0 Count | 4.07 VDC | 0 VDC |
| 1792143672 | 235 Count | 899 Count | 0 Count | 4.07 VDC | 0 VDC |
| 1792142768 | 234 Count | 878 Count | 0 Count | 4.06 VDC | 0 VDC |
| 1792141865 | 233 Count | 860 Count | 0 Count | 4.06 VDC | 0 VDC |
| 1792140961 | 232 Count | 840 Count | 0 Count | 4.06 VDC | 0 VDC |
| 1792140057 | 231 Count | 821 Count | 0 Count | 4.06 VDC | 0 VDC |
| 1792139154 | 230 Count | 794 Count | 0 Count | 4.06 VDC | 0 VDC |
| 1792138250 | 229 Count | 743 Count | 0 Count | 4.06 VDC | 0 VDC |
| 1792137347 | 228 Count | 708 Count | 0 Count | 4.03 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)