This is the latest recevied telemetry packets stored in our database for station/object N7UV-9. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vin* | Isolar* | Tbat* | Tcab* | RX1h* |
|---|---|---|---|---|---|
| 1774134246 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 10 Pkt |
| 1774133646 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 10 Pkt |
| 1774133046 | 13.88 Volt | -25 Amp | -0.01 C | -64.43 C | 20 Pkt |
| 1774132446 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 20 Pkt |
| 1774131846 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 20 Pkt |
| 1774130646 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 30 Pkt |
| 1774130046 | 14.48 Volt | -25 Amp | -0.01 C | -64.43 C | 30 Pkt |
| 1774129446 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 30 Pkt |
| 1774128846 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 20 Pkt |
| 1774128246 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 20 Pkt |
| 1774127646 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 20 Pkt |
| 1774127046 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 20 Pkt |
| 1774125246 | 14.1 Volt | -25 Amp | -0.01 C | -64.43 C | 30 Pkt |
| 1774124646 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 30 Pkt |
| 1774123446 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 30 Pkt |
| 1774122846 | 14.03 Volt | -25 Amp | -0.01 C | -64.43 C | 30 Pkt |
| 1774122246 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 30 Pkt |
| 1774121046 | 14.1 Volt | -25 Amp | -0.01 C | -64.43 C | 30 Pkt |
| 1774120446 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 30 Pkt |
| 1774119847 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 30 Pkt |
| 1774119246 | 14.18 Volt | -25 Amp | -0.01 C | -64.43 C | 30 Pkt |
| 1774118647 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 30 Pkt |
| 1774118047 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 30 Pkt |
| 1774116847 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 40 Pkt |
| 1774115647 | 14.55 Volt | -25 Amp | -0.01 C | -64.43 C | 30 Pkt |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Isolar: 0, 0.1953, -24.9984
Tbat: 0, 0.5033, -64.43
Tcab: 0, 0.5033, -64.43
RX1h: 0, 10, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)