This is the latest recevied telemetry packets stored in our database for station/object S51ZK-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1762312661 | 112 Count | 662 Count | 102 Count | 0 VDC | 0 VDC |
| 1762309058 | 102 Count | 601 Count | 93 Count | 0 VDC | 0 VDC |
| 1762305455 | 91 Count | 542 Count | 83 Count | 0 VDC | 0 VDC |
| 1762301852 | 80 Count | 480 Count | 73 Count | 0 VDC | 0 VDC |
| 1762298249 | 69 Count | 415 Count | 63 Count | 0 VDC | 0 VDC |
| 1762294664 | 58 Count | 347 Count | 53 Count | 0 VDC | 0 VDC |
| 1762291061 | 45 Count | 287 Count | 41 Count | 0 VDC | 0 VDC |
| 1762287458 | 34 Count | 219 Count | 31 Count | 0 VDC | 0 VDC |
| 1762283855 | 22 Count | 139 Count | 20 Count | 0 VDC | 0 VDC |
| 1762280251 | 11 Count | 72 Count | 10 Count | 0 VDC | 0 VDC |
| 1762276648 | 0 Count | 0 Count | 0 Count | 0 VDC | 0 VDC |
| 1762273063 | 140 Count | 991 Count | 127 Count | 0 VDC | 0 VDC |
| 1762269460 | 129 Count | 931 Count | 117 Count | 0 VDC | 0 VDC |
| 1762265857 | 119 Count | 871 Count | 108 Count | 0 VDC | 0 VDC |
| 1762262253 | 108 Count | 816 Count | 98 Count | 0 VDC | 0 VDC |
| 1762258650 | 99 Count | 760 Count | 90 Count | 0 VDC | 0 VDC |
| 1762255050 | 88 Count | 661 Count | 80 Count | 0 VDC | 0 VDC |
| 1762251464 | 79 Count | 572 Count | 72 Count | 0 VDC | 0 VDC |
| 1762247861 | 65 Count | 491 Count | 59 Count | 0 VDC | 0 VDC |
| 1762244258 | 52 Count | 429 Count | 47 Count | 0 VDC | 0 VDC |
| 1762240654 | 43 Count | 356 Count | 39 Count | 0 VDC | 0 VDC |
| 1762237051 | 38 Count | 298 Count | 35 Count | 0 VDC | 0 VDC |
| 1762233448 | 30 Count | 209 Count | 28 Count | 0 VDC | 0 VDC |
| 1762229862 | 19 Count | 141 Count | 18 Count | 0 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)