This is the latest recevied telemetry packets stored in our database for station/object SP8IZA-1. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Tzew* | Twew* | Uzas* | Cisn* | DHT* |
|---|---|---|---|---|---|
| 1836274591 | 11.5 stC | 18.9 stC | 13.33 Volt | 1004.2 hPa | 11 stC |
| 1836274442 | 11.5 stC | 18.9 stC | 13.33 Volt | 1004.1 hPa | 11 stC |
| 1836274291 | 11.5 stC | 18.9 stC | 13.35 Volt | 1004.3 hPa | 11 stC |
| 1836274142 | 11.5 stC | 18.9 stC | 13.35 Volt | 1004.1 hPa | 11 stC |
| 1836273990 | 11.5 stC | 18.9 stC | 13.33 Volt | 1004.3 hPa | 11 stC |
| 1766226790 | 3 stC | 8.4 stC | 13.33 Volt | 1000.1 hPa | 3 stC |
| 1766226490 | 3 stC | 8.5 stC | 13.33 Volt | 1000.1 hPa | 3 stC |
| 1766225588 | 2.9 stC | 8.5 stC | 13.33 Volt | 1000.1 hPa | 3 stC |
| 1766225288 | 2.8 stC | 8.5 stC | 13.33 Volt | 1000.1 hPa | 3 stC |
| 1766224987 | 2.8 stC | 8.5 stC | 13.33 Volt | 1000.2 hPa | 3 stC |
| 1766224687 | 2.8 stC | 8.5 stC | 13.33 Volt | 1000.1 hPa | 3 stC |
| 1766224386 | 2.8 stC | 8.5 stC | 13.33 Volt | 1000.2 hPa | 3 stC |
| 1766224086 | 2.8 stC | 8.5 stC | 13.33 Volt | 1000.2 hPa | 3 stC |
| 1766223785 | 2.7 stC | 8.4 stC | 13.33 Volt | 1000.2 hPa | 3 stC |
| 1766223485 | 2.6 stC | 8.4 stC | 13.33 Volt | 1000.4 hPa | 3 stC |
| 1766223184 | 2.6 stC | 8.4 stC | 13.33 Volt | 1000.5 hPa | 3 stC |
| 1766222884 | 2.5 stC | 8.4 stC | 13.3 Volt | 1000.6 hPa | 3 stC |
| 1766222283 | 2.5 stC | 8.4 stC | 13.33 Volt | 1000.6 hPa | 3 stC |
| 1766221982 | 2.4 stC | 8.4 stC | 13.3 Volt | 1000.6 hPa | 3 stC |
| 1766221682 | 2.3 stC | 8.4 stC | 13.33 Volt | 1000.7 hPa | 2 stC |
| 1766221381 | 2.3 stC | 8.4 stC | 13.33 Volt | 1000.7 hPa | 2 stC |
| 1766221081 | 2.3 stC | 8.3 stC | 13.33 Volt | 1000.7 hPa | 2 stC |
| 1766220780 | 2.4 stC | 8.4 stC | 13.3 Volt | 1000.6 hPa | 3 stC |
| 1766220480 | 2.4 stC | 8.4 stC | 13.33 Volt | 1000.7 hPa | 2 stC |
| 1766220179 | 2.5 stC | 8.4 stC | 13.33 Volt | 1000.6 hPa | 2 stC |
*Used Equation Coefficients:
Tzew: 0, 0.1, -50
Twew: 0, 0.1, -50
Uzas: 0, 0.025, 0
Cisn: 0, 0.1, 950
DHT: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)