This is the latest recevied telemetry packets stored in our database for station/object KC1BAZ-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | RFIn* | RFiGate* | DigiRpt* | Temp* | InetiGate* |
|---|---|---|---|---|---|
| 1836274493 | 14 Pkts | 14 Pkts | 8 Pkts | 32 C | 0 Pkts |
| 1778052576 | 14 Pkts | 14 Pkts | 6 Pkts | 34 C | 0 Pkts |
| 1778048976 | 12 Pkts | 12 Pkts | 5 Pkts | 35 C | 0 Pkts |
| 1778045376 | 18 Pkts | 18 Pkts | 9 Pkts | 35 C | 0 Pkts |
| 1778041776 | 21 Pkts | 21 Pkts | 10 Pkts | 35 C | 0 Pkts |
| 1778038176 | 79 Pkts | 79 Pkts | 18 Pkts | 35 C | 0 Pkts |
| 1778034578 | 42 Pkts | 40 Pkts | 23 Pkts | 35 C | 0 Pkts |
| 1778030981 | 35 Pkts | 35 Pkts | 17 Pkts | 36 C | 0 Pkts |
| 1778027376 | 26 Pkts | 26 Pkts | 14 Pkts | 35 C | 0 Pkts |
| 1778023776 | 28 Pkts | 28 Pkts | 17 Pkts | 35 C | 0 Pkts |
| 1778020176 | 25 Pkts | 25 Pkts | 15 Pkts | 35 C | 0 Pkts |
| 1778016576 | 23 Pkts | 23 Pkts | 14 Pkts | 35 C | 0 Pkts |
| 1778012977 | 49 Pkts | 49 Pkts | 22 Pkts | 35 C | 0 Pkts |
| 1778009377 | 43 Pkts | 43 Pkts | 29 Pkts | 35 C | 0 Pkts |
| 1778005735 | 35 Pkts | 35 Pkts | 22 Pkts | 32 C | 0 Pkts |
| 1778002135 | 41 Pkts | 41 Pkts | 24 Pkts | 32 C | 0 Pkts |
| 1777998535 | 38 Pkts | 38 Pkts | 24 Pkts | 32 C | 0 Pkts |
| 1777994935 | 36 Pkts | 36 Pkts | 17 Pkts | 32 C | 0 Pkts |
| 1777991335 | 27 Pkts | 27 Pkts | 17 Pkts | 31 C | 0 Pkts |
| 1777987735 | 18 Pkts | 18 Pkts | 8 Pkts | 31 C | 0 Pkts |
| 1777984135 | 28 Pkts | 28 Pkts | 15 Pkts | 31 C | 0 Pkts |
| 1777980535 | 37 Pkts | 37 Pkts | 19 Pkts | 31 C | 0 Pkts |
| 1777976935 | 36 Pkts | 36 Pkts | 17 Pkts | 31 C | 0 Pkts |
| 1777973335 | 22 Pkts | 22 Pkts | 12 Pkts | 31 C | 0 Pkts |
| 1777969735 | 27 Pkts | 27 Pkts | 11 Pkts | 31 C | 0 Pkts |
*Used Equation Coefficients:
RFIn: 0, 1, 0
RFiGate: 0, 1, 0
DigiRpt: 0, 1, 0
Temp: 0, 1, 0
InetiGate: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)