This is the latest recevied telemetry packets stored in our database for station/object E24ORD-1. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | RxTraffic* | TxTraffic* | RxDrop* | RSSI* | Voltage* |
|---|---|---|---|---|---|
| 1770113425 | 0 Pkt | 12 Pkt | 33 Pkt | -89 dBm | 0.18 V |
| 1770111436 | 0 Pkt | 10 Pkt | 43 Pkt | -88 dBm | 0.16 V |
| 1770109447 | 1 Pkt | 7 Pkt | 40 Pkt | -87 dBm | 0.18 V |
| 1770107833 | 3 Pkt | 5 Pkt | 37 Pkt | -88 dBm | 0.16 V |
| 1770105463 | 0 Pkt | 9 Pkt | 40 Pkt | -88 dBm | 0.06 V |
| 1770103474 | 0 Pkt | 10 Pkt | 45 Pkt | -89 dBm | 0.16 V |
| 1770101485 | 0 Pkt | 10 Pkt | 40 Pkt | -87 dBm | 0.04 V |
| 1770099495 | 0 Pkt | 10 Pkt | 39 Pkt | -88 dBm | 0.16 V |
| 1770097507 | 0 Pkt | 9 Pkt | 40 Pkt | -86 dBm | 0.14 V |
| 1770095520 | 1 Pkt | 7 Pkt | 34 Pkt | -88 dBm | 0.04 V |
| 1770093529 | 1 Pkt | 10 Pkt | 25 Pkt | -86 dBm | 0.14 V |
| 1770091541 | 1 Pkt | 9 Pkt | 42 Pkt | -86 dBm | 0.18 V |
| 1770089552 | 0 Pkt | 9 Pkt | 41 Pkt | -87 dBm | 0.16 V |
| 1770087563 | 0 Pkt | 12 Pkt | 38 Pkt | -85 dBm | 0.16 V |
| 1770085575 | 1 Pkt | 7 Pkt | 35 Pkt | -89 dBm | 0.02 V |
| 1770083585 | 0 Pkt | 9 Pkt | 38 Pkt | -88 dBm | 0.18 V |
| 1770081597 | 0 Pkt | 12 Pkt | 30 Pkt | -89 dBm | 0.16 V |
| 1770079608 | 1 Pkt | 7 Pkt | 28 Pkt | -88 dBm | 0.16 V |
| 1770077618 | 0 Pkt | 10 Pkt | 41 Pkt | -87 dBm | 0.06 V |
| 1770075630 | 1 Pkt | 10 Pkt | 35 Pkt | -85 dBm | 0.02 V |
| 1770073640 | 1 Pkt | 6 Pkt | 31 Pkt | -85 dBm | 0.06 V |
| 1770071652 | 0 Pkt | 9 Pkt | 32 Pkt | -87 dBm | 0.18 V |
| 1770069663 | 0 Pkt | 13 Pkt | 29 Pkt | -86 dBm | 0.04 V |
| 1770067674 | 0 Pkt | 11 Pkt | 35 Pkt | -86 dBm | 0.08 V |
| 1770065685 | 0 Pkt | 9 Pkt | 34 Pkt | -85 dBm | 0.04 V |
*Used Equation Coefficients:
RxTraffic: 0, 1, 0
TxTraffic: 0, 1, 0
RxDrop: 0, 1, 0
RSSI: 0, -1, 0
Voltage: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)