This is the latest recevied telemetry packets stored in our database for station/object AC3CZ-12. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vin* | Rx1h* | Dg1h* | Eff1h* | As* |
|---|---|---|---|---|---|
| 1836274803 | 14.03 Volt | 90 Pkt | 50 Pkt | 32 Pcnt | 0 |
| 1836273903 | 14.03 Volt | 80 Pkt | 40 Pkt | 29 Pcnt | 0 |
| 1766187836 | 14.03 Volt | 20 Pkt | 20 Pkt | 27 Pcnt | 0 |
| 1766187475 | 14.03 Volt | 20 Pkt | 20 Pkt | 27 Pcnt | 0 |
| 1766186036 | 14.03 Volt | 30 Pkt | 20 Pkt | 43 Pcnt | 0 |
| 1766185855 | 14.03 Volt | 30 Pkt | 20 Pkt | 43 Pcnt | 0 |
| 1766184236 | 14.03 Volt | 40 Pkt | 30 Pkt | 52 Pcnt | 0 |
| 1766184235 | 14.03 Volt | 40 Pkt | 30 Pkt | 52 Pcnt | 0 |
| 1766182615 | 14.03 Volt | 40 Pkt | 30 Pkt | 47 Pcnt | 0 |
| 1766182436 | 14.03 Volt | 40 Pkt | 30 Pkt | 48 Pcnt | 0 |
| 1766180995 | 14.03 Volt | 30 Pkt | 20 Pkt | 44 Pcnt | 0 |
| 1766180636 | 14.03 Volt | 30 Pkt | 20 Pkt | 46 Pcnt | 0 |
| 1766179375 | 14.03 Volt | 20 Pkt | 20 Pkt | 63 Pcnt | 0 |
| 1766178836 | 14.03 Volt | 30 Pkt | 20 Pkt | 65 Pcnt | 0 |
| 1766177756 | 14.03 Volt | 20 Pkt | 20 Pkt | 77 Pcnt | 0 |
| 1766177038 | 14.03 Volt | 20 Pkt | 20 Pkt | 83 Pcnt | 0 |
| 1766176136 | 14.03 Volt | 30 Pkt | 20 Pkt | 85 Pcnt | 0 |
| 1766175236 | 14.03 Volt | 30 Pkt | 20 Pkt | 75 Pcnt | 0 |
| 1766174516 | 14.03 Volt | 30 Pkt | 30 Pkt | 67 Pcnt | 0 |
| 1766173436 | 14.03 Volt | 30 Pkt | 20 Pkt | 59 Pcnt | 0 |
| 1766172896 | 14.03 Volt | 20 Pkt | 20 Pkt | 50 Pcnt | 0 |
| 1766171636 | 14.03 Volt | 20 Pkt | 20 Pkt | 38 Pcnt | 0 |
| 1766171276 | 14.03 Volt | 20 Pkt | 20 Pkt | 38 Pcnt | 0 |
| 1766169836 | 14.03 Volt | 30 Pkt | 30 Pkt | 34 Pcnt | 0 |
| 1766169656 | 14.03 Volt | 30 Pkt | 20 Pkt | 32 Pcnt | 0 |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
As: 0, 0, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)