This is the latest recevied telemetry packets stored in our database for station/object LINCON. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Value1* | Value2* | Value3* | Value4* | Value5* |
|---|---|---|---|---|---|
| 1836274130 | 0 | 0 | 119 | 120 | 133 |
| 1836273950 | 0 | 0 | 120 | 120 | 128 |
| 1778042415 | 0 | 0 | 119 | 119 | 132 |
| 1778041485 | 0 | 0 | 119 | 119 | 132 |
| 1778040555 | 0 | 0 | 119 | 120 | 128 |
| 1778039625 | 0 | 0 | 120 | 120 | 128 |
| 1778038695 | 0 | 0 | 120 | 120 | 126 |
| 1778037765 | 0 | 0 | 119 | 120 | 133 |
| 1778036836 | 0 | 0 | 121 | 121 | 133 |
| 1778035905 | 0 | 0 | 120 | 121 | 128 |
| 1778034975 | 0 | 0 | 119 | 119 | 133 |
| 1778034045 | 0 | 0 | 120 | 120 | 130 |
| 1778033117 | 0 | 0 | 119 | 120 | 126 |
| 1778032185 | 0 | 0 | 119 | 120 | 128 |
| 1778031255 | 0 | 0 | 120 | 121 | 133 |
| 1778030324 | 0 | 0 | 119 | 120 | 128 |
| 1778029395 | 0 | 0 | 121 | 121 | 129 |
| 1778028464 | 0 | 0 | 120 | 120 | 130 |
| 1778027541 | 0 | 0 | 120 | 120 | 130 |
| 1778026604 | 0 | 0 | 118 | 119 | 132 |
| 1778025675 | 0 | 0 | 120 | 120 | 131 |
| 1778024744 | 0 | 0 | 118 | 119 | 133 |
| 1778023814 | 0 | 0 | 120 | 120 | 132 |
| 1778022884 | 0 | 0 | 119 | 120 | 126 |
| 1778021954 | 0 | 0 | 120 | 121 | 133 |
*Used Equation Coefficients:
Value1: 0, 1, 0
Value2: 0, 1, 0
Value3: 0, 1, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)