This is the latest recevied telemetry packets stored in our database for station/object SM0YOS-8. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Value1* | Value2* | Value3* | Value4* | Value5* |
|---|---|---|---|---|---|
| 1786729114 | 125 | 126 | 129 | 0 | 122 |
| 1786725514 | 133 | 135 | 129 | 0 | 129 |
| 1786721915 | 124 | 126 | 129 | 0 | 122 |
| 1786718315 | 133 | 134 | 129 | 0 | 129 |
| 1786714715 | 133 | 134 | 129 | 0 | 129 |
| 1786711115 | 124 | 126 | 129 | 0 | 121 |
| 1786707260 | 142 | 144 | 145 | 0 | 139 |
| 1786707178 | 142 | 144 | 144 | 0 | 139 |
| 1786707098 | 142 | 144 | 144 | 0 | 139 |
| 1786707030 | 142 | 144 | 145 | 0 | 138 |
| 1786706890 | 142 | 144 | 139 | 0 | 138 |
| 1786706825 | 142 | 144 | 139 | 0 | 138 |
| 1786706674 | 142 | 144 | 138 | 0 | 139 |
| 1786706601 | 142 | 144 | 138 | 0 | 138 |
| 1786706419 | 142 | 144 | 139 | 0 | 139 |
| 1786706347 | 142 | 144 | 139 | 0 | 139 |
| 1786706243 | 142 | 144 | 138 | 0 | 138 |
| 1786706139 | 142 | 144 | 139 | 0 | 138 |
| 1786706060 | 142 | 144 | 139 | 0 | 138 |
| 1786705939 | 136 | 138 | 139 | 0 | 132 |
| 1786705866 | 142 | 144 | 139 | 0 | 138 |
| 1786705794 | 142 | 144 | 138 | 0 | 138 |
| 1786705644 | 142 | 144 | 139 | 0 | 139 |
| 1786705538 | 142 | 144 | 139 | 0 | 138 |
| 1786705459 | 142 | 144 | 139 | 0 | 138 |
*Used Equation Coefficients:
Value1: 0, 1, 0
Value2: 0, 1, 0
Value3: 0, 1, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)