This is the latest recevied telemetry packets stored in our database for station/object SP8EBC-11. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Rx10min* | Tx10min* | Digi10min* | Vbatt* | Tempre* |
|---|---|---|---|---|---|
| 1836274411 | 0 Pkt | 6 Pkt | 0 Pkt | 12.58 V | 16.5 DegC |
| 1836274263 | 0 Pkt | 6 Pkt | 0 Pkt | 12.58 V | 16.5 DegC |
| 1774087261 | 0 Pkt | 6 Pkt | 0 Pkt | 13.94 V | 11 DegC |
| 1774086662 | 0 Pkt | 6 Pkt | 0 Pkt | 13.7 V | 11 DegC |
| 1774086059 | 0 Pkt | 6 Pkt | 0 Pkt | 13.56 V | 11.5 DegC |
| 1774085459 | 0 Pkt | 6 Pkt | 0 Pkt | 13.92 V | 11.5 DegC |
| 1774084856 | 0 Pkt | 6 Pkt | 0 Pkt | 13.96 V | 11 DegC |
| 1774084257 | 0 Pkt | 6 Pkt | 0 Pkt | 14 V | 11 DegC |
| 1774083653 | 0 Pkt | 7 Pkt | 0 Pkt | 14.08 V | 10.5 DegC |
| 1774083054 | 0 Pkt | 6 Pkt | 0 Pkt | 13.96 V | 10 DegC |
| 1774082450 | 0 Pkt | 6 Pkt | 0 Pkt | 13.82 V | 9 DegC |
| 1774081851 | 0 Pkt | 6 Pkt | 0 Pkt | 13.18 V | 8 DegC |
| 1774081247 | 0 Pkt | 11 Pkt | 0 Pkt | 12.96 V | 8 DegC |
| 1774080638 | 0 Pkt | 6 Pkt | 0 Pkt | 12.96 V | 7.5 DegC |
| 1774080034 | 0 Pkt | 6 Pkt | 0 Pkt | 12.88 V | 7.5 DegC |
| 1774079435 | 0 Pkt | 6 Pkt | 0 Pkt | 12.9 V | 7.5 DegC |
| 1774078831 | 0 Pkt | 6 Pkt | 0 Pkt | 12.98 V | 8 DegC |
| 1774078232 | 0 Pkt | 6 Pkt | 0 Pkt | 13.08 V | 8 DegC |
| 1774077629 | 0 Pkt | 6 Pkt | 0 Pkt | 13.28 V | 8 DegC |
| 1774077029 | 0 Pkt | 6 Pkt | 0 Pkt | 13.56 V | 8 DegC |
| 1774076425 | 0 Pkt | 7 Pkt | 0 Pkt | 13.66 V | 8 DegC |
| 1774075827 | 0 Pkt | 6 Pkt | 0 Pkt | 13.5 V | 8 DegC |
| 1774075222 | 0 Pkt | 6 Pkt | 0 Pkt | 13.6 V | 8.5 DegC |
| 1774074623 | 0 Pkt | 6 Pkt | 0 Pkt | 14.04 V | 8.5 DegC |
| 1774074020 | 0 Pkt | 6 Pkt | 0 Pkt | 13.32 V | 7 DegC |
*Used Equation Coefficients:
Rx10min: 0, 1, 0
Tx10min: 0, 1, 0
Digi10min: 0, 1, 0
Vbatt: 0, 0.02, 10
Tempre: 0, 0.5, -50
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)