This is the latest recevied telemetry packets stored in our database for station/object F1ZYG-3. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Temperature* | CPU Raspberry* | Value3* | Value4* | Value5* |
---|---|---|---|---|---|
1753714517 | 19.4 | 55.3 | 0 | 0 | 0 |
1753713675 | 19.5 | 54.8 | 0 | 0 | 0 |
1753712835 | 19.8 | 54.8 | 0 | 0 | 0 |
1753711995 | 20 | 54.8 | 0 | 0 | 0 |
1753711156 | 19.8 | 54.8 | 0 | 0 | 0 |
1753710317 | 18.9 | 54.8 | 0 | 0 | 0 |
1753709475 | 18.4 | 54.8 | 0 | 0 | 0 |
1753708634 | 18.4 | 54.8 | 0 | 0 | 0 |
1753707795 | 19.5 | 54.2 | 0 | 0 | 0 |
1753706954 | 19.7 | 54.8 | 0 | 0 | 0 |
1753706116 | 19.7 | 54.2 | 0 | 0 | 0 |
1753705275 | 20.6 | 54.2 | 0 | 0 | 0 |
1753704436 | 20.4 | 53.7 | 0 | 0 | 0 |
1753703595 | 19.8 | 54.8 | 0 | 0 | 0 |
1753702755 | 19.6 | 54.8 | 0 | 0 | 0 |
1753701916 | 19.4 | 53.7 | 0 | 0 | 0 |
1753701075 | 17.8 | 53.7 | 0 | 0 | 0 |
1753700235 | 19.6 | 53.7 | 0 | 0 | 0 |
1753699396 | 19 | 53.7 | 0 | 0 | 0 |
1753698554 | 17.3 | 53.7 | 0 | 0 | 0 |
1753697716 | 18.1 | 53.7 | 0 | 0 | 0 |
1753696874 | 18.4 | 54.2 | 0 | 0 | 0 |
1753696034 | 17.5 | 53.7 | 0 | 0 | 0 |
1753695195 | 16.6 | 54.2 | 0 | 0 | 0 |
1753694356 | 16.6 | 53.7 | 0 | 0 | 0 |
*Used Equation Coefficients:
Temperature: 0, 0.1, 0
CPU Raspberry: 0, 0.1, 0
Value3: 0, 1, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)