This is the latest recevied telemetry packets stored in our database for station/object OE5RGM-20. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Press* | Temp.in* | Hum* | QNH* | Temp.out* |
|---|---|---|---|---|---|
| 1779776065 | 996.6 hPa | 27.1 C deg | 0 % | 1036.3 hPa | 39.7 C deg |
| 1779768804 | 996.3 hPa | 21.4 C deg | 0 % | 1036.8 hPa | 14.4 C deg |
| 1779766989 | 996.2 hPa | 21.3 C deg | 0 % | 1036.6 hPa | 13.6 C deg |
| 1779750654 | 996.4 hPa | 21.2 C deg | 0 % | 1036.8 hPa | 17.7 C deg |
| 1779748839 | 996.5 hPa | 21.4 C deg | 0 % | 1036.9 hPa | 15.9 C deg |
| 1779745209 | 996.1 hPa | 21.5 C deg | 0 % | 1036.5 hPa | 17.8 C deg |
| 1779732503 | 995.3 hPa | 22 C deg | 0 % | 1035.6 hPa | 22.4 C deg |
| 1779723428 | 995.4 hPa | 22.7 C deg | 0 % | 1035.6 hPa | 29.5 C deg |
| 1779714353 | 996.2 hPa | 22.3 C deg | 0 % | 1036.5 hPa | 28.1 C deg |
| 1779712538 | 996.3 hPa | 22.1 C deg | 0 % | 1036.7 hPa | 27.6 C deg |
| 1779710723 | 996.6 hPa | 22 C deg | 0 % | 1037 hPa | 27.3 C deg |
| 1779708908 | 996.9 hPa | 22.2 C deg | 0 % | 1037.3 hPa | 28.2 C deg |
| 1779696203 | 997.9 hPa | 22.4 C deg | 0 % | 1038.2 hPa | 33.3 C deg |
| 1779694388 | 997.8 hPa | 22.5 C deg | 0 % | 1038.2 hPa | 40.9 C deg |
| 1779692573 | 997.8 hPa | 22.8 C deg | 0 % | 1038.1 hPa | 40.1 C deg |
| 1779690758 | 997.8 hPa | 23.6 C deg | 0 % | 1038 hPa | 38.7 C deg |
*Used Equation Coefficients:
Press: 0, 1, 0
Temp.in: 0, 1, 0
Hum: 0, 1, 0
QNH: 0, 1, 0
Temp.out: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)