| Time | CPUTemp* | RxPkts/20m* | RxPkts/1h* | RxPkts/24h* | DiGi* |
|---|---|---|---|---|---|
| 1836274571 | 29.2 C | 2 p | 2 p | 73 p | 1205 p |
| 1770460337 | 12.5 C | 50 p | 59 p | 84 p | 84 p |
| 1770459137 | 12 C | 50 p | 59 p | 84 p | 84 p |
| 1770457937 | 13.4 C | 50 p | 59 p | 84 p | 84 p |
| 1770456738 | 12.8 C | 50 p | 59 p | 84 p | 84 p |
| 1770455537 | 14.3 C | 50 p | 59 p | 84 p | 84 p |
| 1770454339 | 13.2 C | 27 p | 27 p | 52 p | 51 p |
| 1770453137 | 13.4 C | 18 p | 25 p | 25 p | 25 p |
| 1770451938 | 14.3 C | 18 p | 25 p | 25 p | 25 p |
| 1770450738 | 13.9 C | 18 p | 25 p | 25 p | 25 p |
| 1770449537 | 13.7 C | 18 p | 25 p | 25 p | 25 p |
| 1770448337 | 13.4 C | 7 p | 7 p | 7 p | 7 p |
| 1770447137 | 14.4 C | 3 p | 3 p | 3 p | 3 p |
| 1770445938 | 14.7 C | 2 p | 2 p | 3 p | 4912 p |
| 1770444737 | 14.3 C | 2 p | 2 p | 3 p | 4912 p |
| 1770443537 | 13.8 C | 2 p | 2 p | 3 p | 4912 p |
| 1770442337 | 14.8 C | 2 p | 2 p | 3 p | 4912 p |
| 1770441137 | 13.7 C | 2 p | 2 p | 3 p | 4912 p |
| 1770439937 | 14.2 C | 2 p | 2 p | 3 p | 4912 p |
| 1770438737 | 12.8 C | 2 p | 2 p | 3 p | 4912 p |
| 1770437538 | 15.1 C | 2 p | 2 p | 3 p | 4912 p |
| 1770436337 | 13.8 C | 2 p | 2 p | 3 p | 4912 p |
| 1770435137 | 13 C | 2 p | 2 p | 3 p | 4912 p |
| 1770433937 | 10.8 C | 2 p | 2 p | 3 p | 4912 p |
| 1770426573 | 14.9 C | 2 p | 2 p | 3 p | 4912 p |
*Used Equation Coefficients:
CPUTemp: 0, 1, 0
RxPkts/20m: 0, 1, 0
RxPkts/1h: 0, 1, 0
RxPkts/24h: 0, 1, 0
DiGi: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)