This is the latest recevied telemetry packets stored in our database for station/object LZ0DAP-13. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vin:* | Rx1h* | Dg1h* | EffTo* | Temp* |
|---|---|---|---|---|---|
| 1836274290 | 14.32 Volt | 170 Pkt | 0 Pkt | 88 Pcnt | 26.61 C |
| 1836274140 | 14.32 Volt | 170 Pkt | 0 Pkt | 88 Pcnt | 26.75 C |
| 1774101123 | 14.32 Volt | 70 Pkt | 0 Pkt | 88 Pcnt | 24.4 C |
| 1774100523 | 14.32 Volt | 70 Pkt | 0 Pkt | 88 Pcnt | 24.4 C |
| 1774099923 | 14.32 Volt | 70 Pkt | 0 Pkt | 88 Pcnt | 24.4 C |
| 1774099323 | 14.32 Volt | 70 Pkt | 0 Pkt | 88 Pcnt | 23.81 C |
| 1774098723 | 14.32 Volt | 70 Pkt | 0 Pkt | 88 Pcnt | 23.96 C |
| 1774098123 | 14.32 Volt | 70 Pkt | 0 Pkt | 88 Pcnt | 24.11 C |
| 1774097523 | 14.32 Volt | 70 Pkt | 0 Pkt | 88 Pcnt | 24.11 C |
| 1774096923 | 14.32 Volt | 70 Pkt | 0 Pkt | 88 Pcnt | 23.96 C |
| 1774096323 | 14.32 Volt | 70 Pkt | 0 Pkt | 88 Pcnt | 24.11 C |
| 1774095723 | 14.32 Volt | 70 Pkt | 0 Pkt | 88 Pcnt | 24.11 C |
| 1774095123 | 14.32 Volt | 70 Pkt | 0 Pkt | 88 Pcnt | 24.11 C |
| 1774094523 | 14.32 Volt | 60 Pkt | 0 Pkt | 88 Pcnt | 24.11 C |
| 1774093924 | 14.32 Volt | 70 Pkt | 0 Pkt | 88 Pcnt | 23.96 C |
| 1774093324 | 14.32 Volt | 70 Pkt | 0 Pkt | 88 Pcnt | 23.96 C |
| 1774092724 | 14.32 Volt | 60 Pkt | 0 Pkt | 88 Pcnt | 23.96 C |
| 1774092124 | 14.32 Volt | 60 Pkt | 0 Pkt | 88 Pcnt | 23.96 C |
| 1774091524 | 14.32 Volt | 60 Pkt | 0 Pkt | 88 Pcnt | 23.96 C |
| 1774090924 | 14.32 Volt | 60 Pkt | 0 Pkt | 88 Pcnt | 23.96 C |
| 1774090324 | 14.32 Volt | 60 Pkt | 0 Pkt | 88 Pcnt | 24.11 C |
| 1774089724 | 14.32 Volt | 60 Pkt | 0 Pkt | 88 Pcnt | 23.96 C |
| 1774089124 | 14.32 Volt | 60 Pkt | 0 Pkt | 88 Pcnt | 24.11 C |
| 1774088524 | 14.32 Volt | 60 Pkt | 0 Pkt | 88 Pcnt | 23.96 C |
| 1774087924 | 14.32 Volt | 60 Pkt | 0 Pkt | 88 Pcnt | 23.96 C |
*Used Equation Coefficients:
Vin:: 0, 0.077, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
EffTo: 0, 1, 0
Temp: 0, 0.147, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)