This is the latest recevied telemetry packets stored in our database for station/object W6SRR-3. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | DC* | PC Board* | CPU* | Ambient* | Value5* |
---|---|---|---|---|---|
1754182007 | 1356 | 87 | 40.8 | 80.8 | 0 |
1754181108 | 1356 | 86.8 | 40.8 | 80.3 | 0 |
1754180208 | 1356 | 87.9 | 41.3 | 81.8 | 0 |
1754179308 | 1356 | 87.8 | 41.3 | 81.6 | 0 |
1754178406 | 1354 | 87.6 | 40.8 | 81.4 | 0 |
1754177508 | 1356 | 87.5 | 40.8 | 81.3 | 0 |
1754176607 | 1356 | 87.4 | 40.8 | 81 | 0 |
1754175708 | 1356 | 87.1 | 41.3 | 80.8 | 0 |
1754174806 | 1356 | 87 | 40.8 | 80.6 | 0 |
1754173910 | 1358 | 86.7 | 40.2 | 80.4 | 0 |
1754173008 | 1358 | 86.6 | 40.8 | 80.3 | 0 |
1754172110 | 1356 | 86.3 | 40.8 | 80 | 0 |
1754171207 | 1354 | 86.1 | 40.8 | 79.8 | 0 |
1754170309 | 1353 | 86 | 40.8 | 79.7 | 0 |
1754169408 | 1356 | 85.8 | 40.2 | 79.5 | 0 |
1754168509 | 1356 | 85.6 | 40.2 | 79.2 | 0 |
1754167606 | 1354 | 85.4 | 39.7 | 79.1 | 0 |
1754166708 | 1356 | 85.1 | 40.2 | 79 | 0 |
1754165807 | 1351 | 84.9 | 39.7 | 78.8 | 0 |
1754164909 | 1360 | 84.6 | 39.7 | 78.7 | 0 |
1754164006 | 1354 | 84.4 | 39.7 | 78.6 | 0 |
1754163112 | 1354 | 84.3 | 39.7 | 78.5 | 0 |
1754162208 | 1356 | 84.2 | 39.2 | 78.1 | 0 |
1754161309 | 1354 | 83.9 | 38.6 | 77.9 | 0 |
1754160407 | 1354 | 83.6 | 39.2 | 77.7 | 0 |
*Used Equation Coefficients:
DC: 0, 1, 1000
PC Board: 0, 0.1, 0
CPU: 0, 0.1, 0
Ambient: 0, 0.1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)