This is the latest recevied telemetry packets stored in our database for station/object AI0ET-2. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vbatt* | Vsolar* | VbattTemp* | intTemp* | extTemp* |
|---|---|---|---|---|---|
| 1836274707 | 12.77 Volts | 0 Volts | 69 F | 89 F | 68 F |
| 1836274558 | 12.74 Volts | 0 Volts | 68 F | 89 F | 68 F |
| 1836274108 | 12.78 Volts | 0 Volts | 69 F | 90 F | 69 F |
| 1770135614 | 13.15 Volts | 36.7 Volts | 37 F | 33 F | 0 F |
| 1770135014 | 13.13 Volts | 36 Volts | 36 F | 54 F | 32 F |
| 1770134413 | 13.05 Volts | 36.8 Volts | 36 F | 54 F | 32 F |
| 1770133814 | 12.69 Volts | 36.1 Volts | 36 F | 54 F | 31 F |
| 1770133214 | 12.57 Volts | 35.8 Volts | 36 F | 54 F | 31 F |
| 1770132613 | 12.49 Volts | 36 Volts | 36 F | 54 F | 31 F |
| 1770132014 | 12.34 Volts | 34.4 Volts | 36 F | 54 F | 31 F |
| 1770131413 | 12.3 Volts | 32.2 Volts | 36 F | 54 F | 31 F |
| 1770130813 | 12.32 Volts | 34.1 Volts | 36 F | 54 F | 31 F |
| 1770130214 | 12.26 Volts | 33.2 Volts | 36 F | 54 F | 31 F |
| 1770129614 | 12.24 Volts | 13.5 Volts | 37 F | 54 F | 31 F |
| 1770129013 | 12.22 Volts | 22.1 Volts | 37 F | 54 F | 31 F |
| 1770128413 | 12.24 Volts | 12.3 Volts | 37 F | 54 F | 32 F |
| 1770127814 | 12.24 Volts | 11.9 Volts | 37 F | 54 F | 32 F |
| 1770127214 | 12.26 Volts | 9.7 Volts | 37 F | 54 F | 32 F |
| 1770126613 | 12.27 Volts | 1.2 Volts | 37 F | 54 F | 32 F |
| 1770126013 | 12.25 Volts | 0 Volts | 37 F | 54 F | 32 F |
| 1770125414 | 12.27 Volts | 0 Volts | 37 F | 54 F | 32 F |
| 1770124813 | 12.29 Volts | 0 Volts | 37 F | 54 F | 32 F |
| 1770124213 | 12.3 Volts | 0 Volts | 37 F | 54 F | 32 F |
| 1770123614 | 12.3 Volts | 0 Volts | 37 F | 55 F | 32 F |
| 1770123014 | 12.3 Volts | 0 Volts | 37 F | 55 F | 32 F |
*Used Equation Coefficients:
Vbatt: 0, 0.01, 0
Vsolar: 0, 0.01, 0
VbattTemp: 0, 1, 0
intTemp: 0, 1, 0
extTemp: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)