This is the latest recevied telemetry packets stored in our database for station/object W5AUU-3. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Value1* | Value2* | Value3* | Value4* | Value5* |
|---|---|---|---|---|---|
| 1836274667 | 136 | 89 | 26 | 0 | 269 |
| 1836274524 | 136 | 88 | 26 | 0 | 269 |
| 1836274061 | 136 | 89 | 26 | 0 | 269 |
| 1762314417 | 135 | 71 | 26 | 0 | 322 |
| 1762313811 | 135 | 71 | 26 | 0 | 322 |
| 1762313204 | 135 | 71 | 26 | 0 | 321 |
| 1762312597 | 135 | 72 | 26 | 0 | 321 |
| 1762311991 | 135 | 72 | 26 | 0 | 314 |
| 1762311383 | 135 | 72 | 26 | 0 | 314 |
| 1762310777 | 128 | 72 | 25 | 0 | 314 |
| 1762310173 | 135 | 70 | 26 | 0 | 229 |
| 1762309736 | 135 | 72 | 26 | 0 | 313 |
| 1762309130 | 135 | 72 | 26 | 0 | 313 |
| 1762308523 | 135 | 73 | 26 | 0 | 313 |
| 1762307917 | 135 | 73 | 26 | 0 | 312 |
| 1762307311 | 135 | 73 | 26 | 0 | 312 |
| 1762306704 | 135 | 73 | 26 | 0 | 312 |
| 1762306097 | 135 | 73 | 26 | 0 | 312 |
| 1762305490 | 135 | 73 | 26 | 0 | 311 |
| 1762304884 | 132 | 74 | 26 | 0 | 311 |
| 1762304277 | 135 | 74 | 26 | 0 | 311 |
| 1762303671 | 135 | 74 | 26 | 0 | 310 |
| 1762303064 | 135 | 74 | 26 | 0 | 310 |
| 1762302458 | 135 | 74 | 26 | 0 | 309 |
| 1762301852 | 135 | 74 | 26 | 0 | 309 |
*Used Equation Coefficients:
Value1: 0, 1, 0
Value2: 0, 1, 0
Value3: 0, 1, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)