This is the latest recevied telemetry packets stored in our database for station/object SR9POD. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vin* | T_in* | T_out* | Rx1h* | Dg1h* |
|---|---|---|---|---|---|
| 1786728178 | 13.65 Volt | 32 C | 0 C | 290 Pkt | 30 Pkt |
| 1786727578 | 13.65 Volt | 32.5 C | 0 C | 270 Pkt | 30 Pkt |
| 1786726976 | 13.73 Volt | 32.5 C | 0 C | 270 Pkt | 30 Pkt |
| 1786725178 | 13.65 Volt | 33 C | 0 C | 240 Pkt | 20 Pkt |
| 1786724578 | 13.73 Volt | 33.5 C | 0 C | 250 Pkt | 20 Pkt |
| 1786722778 | 13.73 Volt | 33.5 C | 0 C | 260 Pkt | 20 Pkt |
| 1786722178 | 13.73 Volt | 33.5 C | 0 C | 240 Pkt | 10 Pkt |
| 1786721578 | 13.73 Volt | 34 C | 0 C | 230 Pkt | 10 Pkt |
| 1786720979 | 13.73 Volt | 34 C | 0 C | 220 Pkt | 10 Pkt |
| 1786718578 | 13.73 Volt | 34 C | 0 C | 240 Pkt | 10 Pkt |
| 1786717377 | 13.73 Volt | 34 C | 0 C | 250 Pkt | 10 Pkt |
| 1786716778 | 13.73 Volt | 34 C | 0 C | 250 Pkt | 10 Pkt |
| 1786716178 | 13.73 Volt | 34 C | 0 C | 260 Pkt | 20 Pkt |
| 1786713778 | 13.73 Volt | 34 C | 0 C | 220 Pkt | 30 Pkt |
| 1786711378 | 13.73 Volt | 34 C | 0 C | 220 Pkt | 10 Pkt |
| 1786710179 | 13.73 Volt | 34.5 C | 0 C | 200 Pkt | 10 Pkt |
| 1786709578 | 13.73 Volt | 34.5 C | 0 C | 190 Pkt | 10 Pkt |
| 1786707179 | 13.73 Volt | 35 C | 0 C | 310 Pkt | 70 Pkt |
| 1786706579 | 13.73 Volt | 34.5 C | 0 C | 350 Pkt | 90 Pkt |
| 1786705975 | 13.73 Volt | 34.5 C | 0 C | 380 Pkt | 90 Pkt |
| 1786705378 | 13.73 Volt | 34 C | 0 C | 350 Pkt | 70 Pkt |
| 1786703575 | 13.73 Volt | 34.5 C | 0 C | 470 Pkt | 100 Pkt |
| 1786702979 | 13.65 Volt | 34 C | 0 C | 520 Pkt | 90 Pkt |
| 1786702375 | 13.73 Volt | 34 C | 0 C | 560 Pkt | 90 Pkt |
| 1786701181 | 13.65 Volt | 33.5 C | 0 C | 470 Pkt | 50 Pkt |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
T_in: 0, 0.5, -64
T_out: 0, 1, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)