This is the latest recevied telemetry packets stored in our database for station/object ED4ZAJ-3. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vin* | Rx1h* | Dg1h* | Eff1h* | I2* |
|---|---|---|---|---|---|
| 1774087971 | 13.95 Volt | 230 Pkt | 100 Pkt | 90 Pcnt | 829.6 mA |
| 1774084368 | 13.95 Volt | 160 Pkt | 70 Pkt | 88 Pcnt | 829.6 mA |
| 1774080764 | 13.95 Volt | 200 Pkt | 80 Pkt | 88 Pcnt | 829.6 mA |
| 1774077161 | 13.95 Volt | 200 Pkt | 80 Pkt | 88 Pcnt | 829.6 mA |
| 1774073557 | 13.95 Volt | 200 Pkt | 80 Pkt | 93 Pcnt | 829.6 mA |
| 1774069954 | 13.95 Volt | 190 Pkt | 80 Pkt | 91 Pcnt | 829.6 mA |
| 1774066350 | 13.95 Volt | 200 Pkt | 80 Pkt | 93 Pcnt | 829.6 mA |
| 1774062747 | 13.95 Volt | 190 Pkt | 80 Pkt | 90 Pcnt | 829.6 mA |
| 1774059144 | 13.95 Volt | 250 Pkt | 110 Pkt | 90 Pcnt | 829.6 mA |
| 1774055540 | 13.95 Volt | 190 Pkt | 80 Pkt | 89 Pcnt | 829.6 mA |
| 1774051937 | 13.95 Volt | 180 Pkt | 80 Pkt | 97 Pcnt | 829.6 mA |
| 1774048333 | 13.95 Volt | 190 Pkt | 80 Pkt | 95 Pcnt | 829.6 mA |
| 1774044730 | 13.95 Volt | 240 Pkt | 100 Pkt | 96 Pcnt | 829.6 mA |
| 1774041126 | 13.95 Volt | 180 Pkt | 80 Pkt | 91 Pcnt | 829.6 mA |
| 1774037523 | 13.95 Volt | 280 Pkt | 120 Pkt | 95 Pcnt | 829.6 mA |
| 1774033919 | 13.95 Volt | 210 Pkt | 90 Pkt | 93 Pcnt | 829.6 mA |
| 1774030316 | 13.95 Volt | 270 Pkt | 90 Pkt | 84 Pcnt | 829.6 mA |
| 1774026712 | 13.95 Volt | 260 Pkt | 90 Pkt | 82 Pcnt | 829.6 mA |
| 1774023109 | 13.95 Volt | 200 Pkt | 80 Pkt | 88 Pcnt | 829.6 mA |
| 1774019505 | 13.95 Volt | 220 Pkt | 90 Pkt | 89 Pcnt | 829.6 mA |
| 1774015902 | 13.95 Volt | 210 Pkt | 90 Pkt | 86 Pcnt | 829.6 mA |
| 1774012298 | 13.95 Volt | 210 Pkt | 90 Pkt | 84 Pcnt | 829.6 mA |
| 1774008695 | 13.95 Volt | 210 Pkt | 100 Pkt | 87 Pcnt | 829.6 mA |
| 1774005091 | 13.88 Volt | 170 Pkt | 80 Pkt | 88 Pcnt | 829.6 mA |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
I2: 0, 9.76, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)