This is the latest recevied telemetry packets stored in our database for station/object N5QHO-1. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Vin* | Rx1h* | Dg1h* | Eff1h* | Temp* |
|---|---|---|---|---|---|
| 1766218944 | 13.95 Volt | 90 Pkt | 70 Pkt | 70 Pcnt | -64 F |
| 1766215345 | 13.95 Volt | 80 Pkt | 60 Pkt | 93 Pcnt | -64 F |
| 1766211744 | 13.95 Volt | 80 Pkt | 60 Pkt | 89 Pcnt | -64 F |
| 1766208145 | 13.95 Volt | 90 Pkt | 70 Pkt | 92 Pcnt | -64 F |
| 1766204545 | 13.95 Volt | 80 Pkt | 60 Pkt | 90 Pcnt | -64 F |
| 1766200946 | 13.95 Volt | 80 Pkt | 70 Pkt | 85 Pcnt | -64 F |
| 1766197345 | 13.95 Volt | 80 Pkt | 60 Pkt | 83 Pcnt | -64 F |
| 1766193745 | 13.95 Volt | 90 Pkt | 80 Pkt | 92 Pcnt | -64 F |
| 1766190145 | 13.88 Volt | 80 Pkt | 70 Pkt | 100 Pcnt | -64 F |
| 1766186545 | 13.95 Volt | 80 Pkt | 60 Pkt | 100 Pcnt | -64 F |
| 1766182945 | 13.95 Volt | 100 Pkt | 60 Pkt | 99 Pcnt | -64 F |
| 1766179346 | 13.95 Volt | 80 Pkt | 60 Pkt | 100 Pcnt | -64 F |
| 1766175746 | 13.88 Volt | 80 Pkt | 70 Pkt | 100 Pcnt | -64 F |
| 1766172146 | 13.95 Volt | 80 Pkt | 70 Pkt | 100 Pcnt | -64 F |
| 1766168546 | 13.95 Volt | 80 Pkt | 60 Pkt | 100 Pcnt | -64 F |
| 1766164946 | 14.03 Volt | 100 Pkt | 80 Pkt | 100 Pcnt | -64 F |
| 1766161346 | 13.95 Volt | 90 Pkt | 60 Pkt | 64 Pcnt | -64 F |
| 1766157747 | 13.95 Volt | 100 Pkt | 60 Pkt | 61 Pcnt | -64 F |
| 1766150546 | 14.03 Volt | 110 Pkt | 70 Pkt | 70 Pcnt | -64 F |
| 1766146946 | 13.95 Volt | 100 Pkt | 70 Pkt | 71 Pcnt | -64 F |
| 1766143346 | 13.88 Volt | 90 Pkt | 60 Pkt | 69 Pcnt | -64 F |
| 1766139747 | 13.95 Volt | 80 Pkt | 50 Pkt | 68 Pcnt | -64 F |
| 1766136147 | 13.95 Volt | 100 Pkt | 70 Pkt | 84 Pcnt | -64 F |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Temp: 0, 0.5, -64
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)