This is the latest recevied telemetry packets stored in our database for station/object K7OWW-2. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TempIn* | Volt* | Dg1h* | Rx1h* | Eff1h* |
|---|---|---|---|---|---|
| 1791734171 | 48.4 F | 13.5 Volt | 0 Pkt | 20 Pkt | 55 Pcnt |
| 1791732371 | 48.4 F | 13.58 Volt | 0 Pkt | 20 Pkt | 48 Pcnt |
| 1791730571 | 49.3 F | 13.58 Volt | 0 Pkt | 30 Pkt | 58 Pcnt |
| 1791728771 | 49.3 F | 13.5 Volt | 0 Pkt | 20 Pkt | 57 Pcnt |
| 1791725171 | 49.3 F | 13.5 Volt | 0 Pkt | 20 Pkt | 61 Pcnt |
| 1791723371 | 50.2 F | 13.5 Volt | 0 Pkt | 20 Pkt | 65 Pcnt |
| 1791721571 | 50.2 F | 13.5 Volt | 0 Pkt | 20 Pkt | 58 Pcnt |
| 1791719771 | 50.2 F | 13.5 Volt | 0 Pkt | 20 Pkt | 50 Pcnt |
| 1791716171 | 51.1 F | 13.58 Volt | 0 Pkt | 30 Pkt | 57 Pcnt |
| 1791714371 | 51.1 F | 13.5 Volt | 0 Pkt | 20 Pkt | 53 Pcnt |
| 1791712571 | 52 F | 13.58 Volt | 0 Pkt | 20 Pkt | 57 Pcnt |
| 1791710771 | 52 F | 13.5 Volt | 0 Pkt | 20 Pkt | 58 Pcnt |
| 1791708971 | 52 F | 13.58 Volt | 0 Pkt | 20 Pkt | 61 Pcnt |
| 1791707180 | 52 F | 13.58 Volt | 0 Pkt | 20 Pkt | 58 Pcnt |
| 1791705372 | 52.9 F | 13.58 Volt | 0 Pkt | 30 Pkt | 56 Pcnt |
| 1791703572 | 52.9 F | 13.58 Volt | 0 Pkt | 30 Pkt | 60 Pcnt |
| 1791701772 | 52.9 F | 13.58 Volt | 0 Pkt | 30 Pkt | 64 Pcnt |
| 1791699972 | 53.8 F | 13.58 Volt | 0 Pkt | 30 Pkt | 62 Pcnt |
| 1791698172 | 53.8 F | 13.58 Volt | 0 Pkt | 30 Pkt | 62 Pcnt |
| 1791696372 | 53.8 F | 13.58 Volt | 0 Pkt | 30 Pkt | 64 Pcnt |
| 1791694572 | 53.8 F | 13.58 Volt | 0 Pkt | 30 Pkt | 67 Pcnt |
| 1791692772 | 54.7 F | 13.58 Volt | 0 Pkt | 30 Pkt | 71 Pcnt |
| 1791689172 | 54.7 F | 13.58 Volt | 0 Pkt | 30 Pkt | 67 Pcnt |
| 1791687372 | 54.7 F | 13.58 Volt | 0 Pkt | 30 Pkt | 68 Pcnt |
| 1791685572 | 54.7 F | 13.58 Volt | 0 Pkt | 30 Pkt | 66 Pcnt |
*Used Equation Coefficients:
TempIn: 0, 0.9, -83
Volt: 0, 0.075, 0
Dg1h: 0, 10, 0
Rx1h: 0, 10, 0
Eff1h: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)