This is the latest recevied telemetry packets stored in our database for station/object XE2CT-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Vin* | Rx1h* | Dg1h* | Eff1h* | TEMP* |
---|---|---|---|---|---|
1750290254 | 12.3 Volt | 10 Pkt | 10 Pkt | 57 Pcnt | 32.5 C |
1750289954 | 12.3 Volt | 10 Pkt | 10 Pkt | 60 Pcnt | 32.5 C |
1750289654 | 12.3 Volt | 10 Pkt | 10 Pkt | 60 Pcnt | 32.5 C |
1750289354 | 12.3 Volt | 10 Pkt | 10 Pkt | 61 Pcnt | 32.5 C |
1750289054 | 12.3 Volt | 10 Pkt | 10 Pkt | 70 Pcnt | 32.5 C |
1750288754 | 12.3 Volt | 10 Pkt | 10 Pkt | 70 Pcnt | 32.5 C |
1750288454 | 12.3 Volt | 10 Pkt | 10 Pkt | 70 Pcnt | 33 C |
1750288154 | 12.3 Volt | 10 Pkt | 10 Pkt | 66 Pcnt | 32.5 C |
1750287854 | 12.3 Volt | 10 Pkt | 10 Pkt | 70 Pcnt | 33 C |
1750287554 | 12.3 Volt | 10 Pkt | 10 Pkt | 76 Pcnt | 33 C |
1750287254 | 12.3 Volt | 10 Pkt | 10 Pkt | 78 Pcnt | 33.5 C |
1750286954 | 12.3 Volt | 10 Pkt | 10 Pkt | 80 Pcnt | 33.5 C |
1750286654 | 12.3 Volt | 10 Pkt | 10 Pkt | 75 Pcnt | 33.5 C |
1750286354 | 12.3 Volt | 10 Pkt | 10 Pkt | 76 Pcnt | 33.5 C |
1750286054 | 12.3 Volt | 10 Pkt | 10 Pkt | 70 Pcnt | 33 C |
1750285754 | 12.3 Volt | 10 Pkt | 10 Pkt | 72 Pcnt | 33 C |
1750285454 | 12.3 Volt | 10 Pkt | 10 Pkt | 70 Pcnt | 33 C |
1750285154 | 12.3 Volt | 10 Pkt | 10 Pkt | 73 Pcnt | 33.5 C |
1750284854 | 12.3 Volt | 10 Pkt | 10 Pkt | 70 Pcnt | 33.5 C |
1750284554 | 12.3 Volt | 10 Pkt | 10 Pkt | 76 Pcnt | 33.5 C |
1750284254 | 12.3 Volt | 10 Pkt | 10 Pkt | 78 Pcnt | 34 C |
1750283954 | 12.3 Volt | 10 Pkt | 10 Pkt | 75 Pcnt | 34.5 C |
1750283654 | 12.3 Volt | 10 Pkt | 10 Pkt | 75 Pcnt | 34.5 C |
1750283354 | 12.3 Volt | 10 Pkt | 10 Pkt | 81 Pcnt | 34.5 C |
1750283054 | 12.3 Volt | 10 Pkt | 10 Pkt | 80 Pcnt | 34.5 C |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
TEMP: 0, 0.5, -64
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)