This is the latest recevied telemetry packets stored in our database for station/object VA7GFZ-13. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Vin* | Temp* | Rx1h* | Eff1h* | A5* |
---|---|---|---|---|---|
1758236163 | 27.6 Volt | 15.5 C | 0 Pkt | 910 Pcnt | 0 None |
1758233402 | 27.6 Volt | 14.5 C | 0 Pkt | 910 Pcnt | 0 None |
1758230642 | 27.8 Volt | 13.5 C | 0 Pkt | 910 Pcnt | 0 None |
1758227884 | 27.8 Volt | 11.5 C | 0 Pkt | 910 Pcnt | 0 None |
1758225122 | 28.4 Volt | 10 C | 0 Pkt | 910 Pcnt | 0 None |
1758208563 | 27.8 Volt | 1 C | 0 Pkt | 910 Pcnt | 0 None |
1758205805 | 25.2 Volt | 1 C | 0 Pkt | 910 Pcnt | 0 None |
1758203045 | 25 Volt | 1.5 C | 0 Pkt | 910 Pcnt | 0 None |
1758200285 | 25 Volt | 1.5 C | 0 Pkt | 910 Pcnt | 0 None |
1758197527 | 25 Volt | 1.5 C | 0 Pkt | 910 Pcnt | 0 None |
1758194765 | 25.2 Volt | 1.5 C | 0 Pkt | 910 Pcnt | 0 None |
1758189245 | 25.2 Volt | 2.5 C | 0 Pkt | 910 Pcnt | 0 None |
1758183725 | 25.2 Volt | 3.5 C | 0 Pkt | 910 Pcnt | 0 None |
1758180965 | 25.4 Volt | 4 C | 0 Pkt | 910 Pcnt | 0 None |
1758178205 | 25.4 Volt | 5 C | 0 Pkt | 910 Pcnt | 0 None |
1758175445 | 25.4 Volt | 6 C | 0 Pkt | 910 Pcnt | 0 None |
1758169925 | 25.6 Volt | 8 C | 0 Pkt | 910 Pcnt | 0 None |
1758167166 | 25.6 Volt | 9.5 C | 0 Pkt | 910 Pcnt | 0 None |
1758161645 | 27.6 Volt | 11 C | 0 Pkt | 910 Pcnt | 0 None |
1758158885 | 28.8 Volt | 11.5 C | 0 Pkt | 910 Pcnt | 0 None |
1758156126 | 28.4 Volt | 11.5 C | 0 Pkt | 910 Pcnt | 0 None |
1758153364 | 29 Volt | 11 C | 0 Pkt | 910 Pcnt | 0 None |
1758150604 | 27.8 Volt | 11.5 C | 0 Pkt | 910 Pcnt | 0 None |
*Used Equation Coefficients:
Vin: 0, 0.2, 0
Temp: 0, 0.5, -64
Rx1h: 0, 10, 0
Eff1h: 0, 10, 0
A5: 0, 0, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)