This is the latest recevied telemetry packets stored in our database for station/object YO3JAZ-NC. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Temp* | Power* | Load* | RSSI* | Vcc* |
|---|---|---|---|---|---|
| 1836274756 | 21.5 C | 0 W | 7.2 % | -57 dBm | 3.42 V |
| 1836274396 | 21.5 C | 0 W | 7.2 % | -55 dBm | 3.42 V |
| 1836274366 | 21.5 C | 0 W | 7.2 % | -55 dBm | 3.43 V |
| 1836274036 | 21.5 C | 0 W | 7.6 % | -55 dBm | 3.43 V |
| 1774108043 | 13.5 C | 280 W | 7.6 % | -60 dBm | 3.44 V |
| 1774107682 | 13.5 C | 300 W | 7.6 % | -59 dBm | 3.43 V |
| 1774107322 | 13.5 C | 320 W | 7.2 % | -60 dBm | 3.44 V |
| 1774106963 | 13.5 C | 320 W | 7.6 % | -60 dBm | 3.44 V |
| 1774106602 | 13.5 C | 340 W | 7.2 % | -60 dBm | 3.44 V |
| 1774106242 | 13.5 C | 340 W | 7.6 % | -60 dBm | 3.44 V |
| 1774105882 | 13.5 C | 320 W | 7.2 % | -60 dBm | 3.44 V |
| 1774105522 | 13.5 C | 320 W | 7.2 % | -60 dBm | 3.44 V |
| 1774105162 | 13.5 C | 300 W | 7.2 % | -59 dBm | 3.44 V |
| 1774104802 | 13.5 C | 320 W | 7.2 % | -59 dBm | 3.44 V |
| 1774104442 | 13.5 C | 340 W | 7.6 % | -60 dBm | 3.43 V |
| 1774104082 | 13.5 C | 680 W | 7.2 % | -59 dBm | 3.44 V |
| 1774103722 | 13.5 C | 700 W | 7.6 % | -59 dBm | 3.44 V |
| 1774103362 | 13.5 C | 840 W | 7.2 % | -60 dBm | 3.44 V |
| 1774103002 | 13.5 C | 900 W | 7.6 % | -59 dBm | 3.44 V |
| 1774102642 | 13.5 C | 720 W | 7.6 % | -59 dBm | 3.44 V |
| 1774102282 | 13.5 C | 660 W | 7.6 % | -59 dBm | 3.44 V |
| 1774101922 | 13.5 C | 640 W | 7.2 % | -59 dBm | 3.43 V |
| 1774101562 | 13.5 C | 640 W | 7.6 % | -59 dBm | 3.43 V |
| 1774101202 | 13.5 C | 640 W | 7.6 % | -59 dBm | 3.43 V |
| 1774100842 | 13.5 C | 640 W | 7.6 % | -59 dBm | 3.44 V |
*Used Equation Coefficients:
Temp: 0, 0.5, -25
Power: 0, 20, 0
Load: 0, 0.4, 0
RSSI: 0, -1, 0
Vcc: 0, 0.01, 2.5
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)