This is the latest recevied telemetry packets stored in our database for station/object HS4NIY-1. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | RxTraffic* | TxTraffic* | RxDrop* | RSSI* | Voltage* |
---|---|---|---|---|---|
1758237487 | 0 Pkt | 0 Pkt | 0 Pkt | -83 dBm | 9.43 V |
1758236797 | 1 Pkt | 0 Pkt | 0 Pkt | -82 dBm | 4.35 V |
1758236107 | 0 Pkt | 0 Pkt | 1 Pkt | -83 dBm | 0.7 V |
1758235418 | 0 Pkt | 0 Pkt | 0 Pkt | -84 dBm | 0.18 V |
1758234728 | 0 Pkt | 0 Pkt | 0 Pkt | -84 dBm | 0.16 V |
1758234038 | 0 Pkt | 0 Pkt | 0 Pkt | -83 dBm | 0.14 V |
1758233349 | 0 Pkt | 0 Pkt | 0 Pkt | -83 dBm | 0.16 V |
1758232659 | 0 Pkt | 1 Pkt | 0 Pkt | -82 dBm | 0.16 V |
1758231970 | 0 Pkt | 0 Pkt | 0 Pkt | -84 dBm | 0.14 V |
1758231280 | 0 Pkt | 0 Pkt | 1 Pkt | -84 dBm | 0.14 V |
1758230590 | 0 Pkt | 1 Pkt | 0 Pkt | -83 dBm | 0.29 V |
1758229900 | 0 Pkt | 0 Pkt | 0 Pkt | -83 dBm | 0.29 V |
1758229211 | 0 Pkt | 0 Pkt | 0 Pkt | -84 dBm | 0.16 V |
1758228521 | 1 Pkt | 0 Pkt | 0 Pkt | -83 dBm | 0.14 V |
1758227832 | 0 Pkt | 0 Pkt | 0 Pkt | -83 dBm | 0.16 V |
1758227142 | 1 Pkt | 0 Pkt | 0 Pkt | -84 dBm | 0.14 V |
1758226453 | 0 Pkt | 0 Pkt | 0 Pkt | -85 dBm | 0.14 V |
1758225763 | 0 Pkt | 0 Pkt | 0 Pkt | -83 dBm | 0.16 V |
1758225074 | 0 Pkt | 0 Pkt | 0 Pkt | -84 dBm | 0.29 V |
1758224384 | 0 Pkt | 0 Pkt | 0 Pkt | -83 dBm | 0.14 V |
1758223694 | 0 Pkt | 0 Pkt | 0 Pkt | -83 dBm | 0.14 V |
1758223005 | 1 Pkt | 0 Pkt | 0 Pkt | -84 dBm | 0.14 V |
1758222315 | 0 Pkt | 1 Pkt | 0 Pkt | -84 dBm | 0.14 V |
1758221625 | 0 Pkt | 0 Pkt | 0 Pkt | -84 dBm | 0.14 V |
1758220936 | 1 Pkt | 0 Pkt | 0 Pkt | -85 dBm | 0.14 V |
*Used Equation Coefficients:
RxTraffic: 0, 1, 0
TxTraffic: 0, 1, 0
RxDrop: 0, 1, 0
RSSI: 0, -1, 0
Voltage: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)