This is the latest recevied telemetry packets stored in our database for station/object E25ZZZ. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | RxTraffic* | TxTraffic* | RxDrop* | RSSI* | Voltage* |
|---|---|---|---|---|---|
| 1836274562 | 0 Pkt | 0 Pkt | 0 Pkt | -56 dBm | 0.43 V |
| 1778049897 | 0 Pkt | 0 Pkt | 0 Pkt | -52 dBm | 0.45 V |
| 1778048973 | 0 Pkt | 0 Pkt | 0 Pkt | -54 dBm | 0 V |
| 1778048049 | 0 Pkt | 0 Pkt | 0 Pkt | -56 dBm | 0.31 V |
| 1778047125 | 0 Pkt | 0 Pkt | 0 Pkt | -55 dBm | 0.06 V |
| 1778046200 | 0 Pkt | 0 Pkt | 0 Pkt | -53 dBm | 0.04 V |
| 1778045276 | 0 Pkt | 0 Pkt | 0 Pkt | -56 dBm | 0.06 V |
| 1778044352 | 0 Pkt | 0 Pkt | 0 Pkt | -58 dBm | 0.1 V |
| 1778043428 | 0 Pkt | 0 Pkt | 0 Pkt | -56 dBm | 0.35 V |
| 1778042504 | 0 Pkt | 0 Pkt | 0 Pkt | -56 dBm | 0.02 V |
| 1778041579 | 0 Pkt | 0 Pkt | 0 Pkt | -54 dBm | 0.27 V |
| 1778040655 | 0 Pkt | 0 Pkt | 0 Pkt | -57 dBm | 0.06 V |
| 1778039731 | 0 Pkt | 0 Pkt | 0 Pkt | -52 dBm | 0.41 V |
| 1778038807 | 0 Pkt | 0 Pkt | 0 Pkt | -55 dBm | 0.27 V |
| 1778037883 | 0 Pkt | 0 Pkt | 0 Pkt | -53 dBm | 0.04 V |
| 1778036959 | 0 Pkt | 0 Pkt | 0 Pkt | -54 dBm | 0.06 V |
| 1778036034 | 0 Pkt | 0 Pkt | 0 Pkt | -57 dBm | 0 V |
| 1778035110 | 0 Pkt | 0 Pkt | 0 Pkt | -55 dBm | 0.1 V |
| 1778034186 | 0 Pkt | 0 Pkt | 0 Pkt | -57 dBm | 0.31 V |
| 1778033262 | 0 Pkt | 0 Pkt | 0 Pkt | -55 dBm | 0.14 V |
| 1778032338 | 0 Pkt | 0 Pkt | 0 Pkt | -55 dBm | 0.06 V |
| 1778031414 | 0 Pkt | 0 Pkt | 0 Pkt | -54 dBm | 0.35 V |
| 1778030490 | 0 Pkt | 0 Pkt | 0 Pkt | -54 dBm | 0.49 V |
| 1778029565 | 0 Pkt | 0 Pkt | 0 Pkt | -57 dBm | 0 V |
| 1778028641 | 0 Pkt | 0 Pkt | 0 Pkt | -53 dBm | 0.39 V |
*Used Equation Coefficients:
RxTraffic: 0, 1, 0
TxTraffic: 0, 1, 0
RxDrop: 0, 1, 0
RSSI: 0, -1, 0
Voltage: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)