This is the latest recevied telemetry packets stored in our database for station/object KJ5IK-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Vin* | Rx1h* | Dg1h* | Eff1h* | Temp* |
---|---|---|---|---|---|
1732289119 | 14.03 Volt | 0 Pkt | 0 Pkt | 30 Pcnt | 67.1 F |
1732288219 | 14.03 Volt | 0 Pkt | 0 Pkt | 26 Pcnt | 65.3 F |
1732287319 | 14.03 Volt | 0 Pkt | 0 Pkt | 40 Pcnt | 52.7 F |
1732286420 | 14.03 Volt | 20 Pkt | 10 Pkt | 67 Pcnt | 48.2 F |
1732285520 | 14.03 Volt | 30 Pkt | 10 Pkt | 63 Pcnt | 47.3 F |
1732284620 | 14.03 Volt | 30 Pkt | 20 Pkt | 67 Pcnt | 46.4 F |
1732283720 | 14.03 Volt | 40 Pkt | 10 Pkt | 67 Pcnt | 44.6 F |
1732282820 | 14.03 Volt | 30 Pkt | 0 Pkt | 63 Pcnt | 44.6 F |
1732281920 | 14.03 Volt | 30 Pkt | 0 Pkt | 64 Pcnt | 45.5 F |
1732281020 | 14.03 Volt | 40 Pkt | 0 Pkt | 67 Pcnt | 42.8 F |
1732280120 | 14.03 Volt | 40 Pkt | 0 Pkt | 65 Pcnt | 42.8 F |
1732279220 | 14.03 Volt | 40 Pkt | 0 Pkt | 73 Pcnt | 42.8 F |
1732278320 | 14.03 Volt | 40 Pkt | 0 Pkt | 74 Pcnt | 42.8 F |
1732277420 | 14.03 Volt | 40 Pkt | 0 Pkt | 64 Pcnt | 42.8 F |
1732276520 | 14.03 Volt | 50 Pkt | 0 Pkt | 68 Pcnt | 42.8 F |
1732275620 | 14.03 Volt | 40 Pkt | 0 Pkt | 68 Pcnt | 43.7 F |
1732274720 | 14.03 Volt | 40 Pkt | 0 Pkt | 72 Pcnt | 42.8 F |
1732273820 | 14.03 Volt | 50 Pkt | 0 Pkt | 86 Pcnt | 43.7 F |
1732272920 | 14.03 Volt | 30 Pkt | 0 Pkt | 90 Pcnt | 43.7 F |
1732272020 | 14.03 Volt | 30 Pkt | 0 Pkt | 91 Pcnt | 43.7 F |
1732271120 | 14.03 Volt | 20 Pkt | 0 Pkt | 87 Pcnt | 43.7 F |
1732270220 | 14.03 Volt | 20 Pkt | 0 Pkt | 89 Pcnt | 44.6 F |
1732269320 | 14.03 Volt | 20 Pkt | 0 Pkt | 84 Pcnt | 45.5 F |
1732268420 | 14.03 Volt | 30 Pkt | 0 Pkt | 91 Pcnt | 45.5 F |
1732267520 | 14.03 Volt | 30 Pkt | 0 Pkt | 89 Pcnt | 45.5 F |
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Temp: 0, 0.9, -83.2
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)